Manual
2. Installation
24
2.3.2 Installing the Main Body
[1] Mounting Method
Fixation to a mating component with a profile of hole since the body is in a cylindrical profile.
φ
d
B
A
Caution label
Dimensions for Body Attachment
Type
O.D. of Pipe
Id (tolerance)
Pipe fixable range
A
Available range for
screw fixing type B
RA1L 16 (0/-0.1) 90 30
RA2L 20 (0/-0.1) 115 40
RA3L 25 (0/-0.1) 164 55
Recommended Fixing Method
Clamping (split clamp)
Clamp with a profile of hole that suits the pipe.
Do not attempt to clamp with a flat plate, nor a profile of the hole, because it may deform the pipe.