13. Frequency Analysis Function for SCON-CA
Controller Anti-Vibration Control
214
13.2 Explanation of Each Window
13.2.1 Measurement Data Selection Window
This window is used to select measurement data.
Click the Parameter (P) menu, point to Controller Parameter Setup (C), and then select Frequency
Analysis for Vibration Control (F), and the measurement data selection window will appear.
Fig. 13.6 Measurement Data Selection (“Import New Controller Data” Selected)
[1] Import new controller data
Select this option if you want to move the connected actuator and import (sample) measurement data to
extract and set the vibration frequency of the load.
The frequency analysis for vibration control window appears where you can perform FFT analysis of the
imported measurement data (sampled data).
Select the axis number under which to set the vibration frequency of the load.
Fig. 13.7 Measurement Data Selection
[1] Import new controller data
[2] Read external measurement data file
[3] Read analytical already data file
[1] Select the axis number under which to import controller data.