Manual

13. Frequency Analysis Function for SCON-CA
Controller Anti-Vibration Control
239
(2) If “Import new controller data” has been selected, move the actuator to import analysis data.
[1] The “sampling” window (new controller data) appears.
Fig. 13.44 Sampling Window
[2] Under “Select data type” on the “Sampling” tab, select the data type you want to import during sampling.
Multiple data types can be selected.
[3] To start actuator operation simultaneously as sampling is started, select the “Link start drive” check box
on the “Sampling” tab and set the position numbers of two points between which the actuator will move
back and forth in the “Start No” and “End No” fields.
[4] Set the wait time in the “Wait time” field.
(Note) Steps [2] to [4] can be performed in any order.
[1] Tool buttons
[2] Sampling/FFT analysis result window switching [5] Measurement data
[6] Data to be analyzed[4] Sampling setting
[3] FFT analysis setting