Owner manual

34
(2) All Clear:
The data of all the position numbers is cleared.
The position data table becomes as shown below.
No. Position Vel Acc Dcl Push LoTh Range Zone + Zone -
Acc/Dcl
Mode
ABS/INC
Cmnd
Mode
Stop
Mode
0 0.00
125
mm/s
0.20 G 0.20 G 0 % 0 % 0.10 mm
0.00
mm
0.00
mm
0 0 0 0
1 50.00
100
mm/s
0.10 G 0.10 G 0 % 0 % 0.20 mm
0.00
mm
0.00
mm
0 0 0 0
2 80.00
100
mm/s
0.10 G 0.10 G 40 % 0 % 5.00 mm
0.00
mm
0.00
mm
0 0 0 0
3 10.00
20
mm/s
0.20 G 0.20 G 0 % 0 % 0.10 mm
0.00
mm
0.00
mm
0 1 0 0
No. Position Vel Acc Dcl Push LoTh Range Zone + Zone -
Acc/Dcl
Mode
ABS/INC
Cmnd
Mode
Stop
Mode
0 * * mm/s * G * G * % * % * mm * mm * mm * * * *
1 * * mm/s * G * G * % * % * mm * mm * mm * * * *
2 * * mm/s * G * G * % * % * mm * mm * mm * * * *
3 * * mm/s * G * G * % * % * mm * mm * mm * * * *
Slct Mode/M2 A. 00
* Edit
In the Mode Select Screen, using the
keys, select Edit and then, press the Return key.
Edit A. 00
*
A
ll Clear
In the Teach/Play Screen, using the
keys,
select All Clear and then, press the Return key.
Pressing 1 on the Numeric keys will clear all data and
then, the screen will return to the Edit Screen. To
cancel, press 0.
In either case, the screen will return to the previous
screen.
Edit A. 00
*
A
ll Clear
Slct Mode A. 00
* Edit
Press the key once to return the screen to the
Mode Select Screen.
All Clear? A. 00
Y Æ 1 N Æ 0