User Manual
Appendix
103
Appendix
Distance from point of action
Flat Type (F45, 55) - Moments and Loading Capacity
The directions of moments generated around the flat type are shown in the figure below.
The points of action of Ma and Mb moments are shown in the figure below.
Point of action Point of action
If the flat type is used horizontally, make sure the load applied to the end of the plate does not exceed the Ma
moment. Refer to the table below listing the allowable loads at the tip as calculated from the Ma moment at each
stroke.
Stroke 50 100 150 200 250 300
Distance from point of action (m)
0.06 0.11 0.16 0.21 0.26 0.31
N 45.0 24.5 16.9 12.9 10.4 8.7
F45 type
(kgf) 4.59 2.50 1.72 1.31 1.06 0.89
Distance from point of action (m)
0.07 0.12 0.17 0.22 0.27 0.32
N 64.3 37.5 26.5 20.5 16.7 14.1
F 55 type
(kgf) 6.56 3.83 2.70 2.09 1.70 1.43
Point of action