User guide
31
Acceleration/deceleration
set in (4)
Acceleration/deceleration
set in (4)
Maximum acceleration
according to the load
Speed
Speed
Moving distance
Moving distance
(7) Acceleration only MAX
(ACC MAX)
Select the specified acceleration or maximum acceleration by entering
“0” or “1.”
The default value is “0.”
0: Specified acceleration --- The value entered in (4) becomes the
actual acceleration/deceleration.
1: Maximum acceleration --- The maximum acceleration set according
to the load is used.
The deceleration conforms to the value
entered in (4).
(7) Acceleration only MAX = 0 (7) Acceleration only MAX = 1
Caution: As a rough guide, enable the acceleration only MAX setting when the actual payload is no more than
one-third of the rated loading capacity.
Check the rated loading capacity of your actuator by referring to the supplied specification list of
supported actuators.