Manual

6. Installation
-34-
Actuator mounting plate
Actuator
6.2 Short Types (Tapped-hole Mounting Types)
RP5N
6.2.1 Installation of Actuator
Install the actuator by guiding it through a hole of approx. 5 to 10 mm provided in a smooth plate.
x Use the tapped hole on the actuator to install the actuator onto the actuator mounting plate.
x The base of the male thread on the actuator side has a tolerance of h8. Use this part as a pilot section.
z RP5N
Tightening torque
Type Tapped hole size
Plate is made of steel
material
Plate is made of
aluminum material
RP5N M5, depth 10 7.27 Nxm 3.42 Nxm
Tapped mounting hole