5.7 Cleanroom Specification
5.7.1 Suction Rate
Air inside the actuator must be suctioned to ensure that the actuator operates in conformance with the
requirements of cleanliness class 10.
Provide an air tube and connect it to a quick joint (outer diameter
6) provided at the suction section, and
connect the other end of the tube to a vacuum pump, blower, ejector, etc., to suction at an applicable flow rate
as specified below.
[RCS2CR]
Lead
2.5 mm/3 mm
5 mm/6 mm
10 mm/12 mm/16 mm
10 mm (SS8)
20 mm
[RCS3(P)CR]
daeL epyT
nim/IN 03 mm 5 8AS
mm 01 8AS
nim/IN 011 mm 02 8AS
30 mm (speed not exceeding
1500 mm/s)
1500 mm/s)
30 mm (speed exceeding
nim/IN 03 mm 5 8SS
SS8
nim/IN 08 mm 01
SS8
nim/IN 021 mm 02
SS8
30 mm (speed not exceeding
1500 mm/s)
160 NI/min
SS8
30 mm (speed exceeding
1500 mm/s)
5.7.2 Suction Joint
Remove the plug from either quick joint and insert an air tube to suction air from either the motor side or counter-
motor side.
Remember to cover the unused joint with a plug.
Plug
Quick joint
Quick joint
RCS2-SA4, SA5, SA6 Outer diameter 6
RCS2-SA7, SS7 Outer diameter
8
RCS2-SS8 Outer diameter
12
RCS3(P) CR-SA8 Outer diameter
10
RCS3(P) CR-SS8 Outer diameter
10
Air tube (provided by the customer)
suction rate
Recommended
15 NI/min
30 NI/min
50 NI/min
40 NI/min
80 NI/min
suction rate
Recommended
160 NI/min
190 NI/min
130 NI/min
60 NI/min
8AS
8AS
Caution:
The clean room types listed below cannot be guaranteed to meet Cleanliness Class 10 if they
are installed in the vertical orientation, the horizontally wall mounted orientation or in the ceiling
mounted orientation since they do not possess a structure to grip the stainless steel sheet from
the side cover.
Please contact us if it is necessary to install the following models in an orientation other than the
horizontal orientation.
Actuator Model : RCS2CR-SA5D, RCS2CR-SA6D