7. Setting the Home
64
7.5 How to Set the Home Preset and Home Return Offset
To correct a position deviation, change the home preset parameter if you are using an X-SEL or SSEL controller,
or change the home return offset parameter if you are using a SCON controller. How to set these parameters is
explained below.
7.5.1 X-SEL or SSEL Controller
(1) Open the position edit screen.
On the PC software screen, click , select [Select Position No.], and then click [OK]. The following
screen will appear.
(2) Compare the current position and the position of the desired position number you have selected, to check
the difference between the two.
The current position
is displayed here
Position number
[2] Click the [MV] button
[1] Select the position you want to
move the actuator to.
Click this button and select a desired position
number on the position edit screen.