If multiple units of IAI’ s PS24 are connected in parallel (upto five PS24s can be connected) to supply power to the
ROBONET, wire them as shown below.
[1] As shown above, connect all PS24s in parallel at the terminal block.
[2] Use a twisted pair cable to wire each power supply to the terminal block.
[3] The twisted pair cables connecting the respective power supplies to the terminal block should be of the same wire size
(recommended: AWG16 to 18) and same length whenever possible.
[4] For the wiring between the terminal block and ROBONET, provide cables in the same thickness, make them a twisted
pair and as short as possible. It is recommended that the power is to be supplied from the units on the sides of
ROBONET.