User guide

Page 131
Chapter 4. Programming
[Function] While the designated input port or flag (global flag) is ON, the axis moves backward.
* HOLD is not available for this command.
[Example] JBWN 10000011 25
When input port 25 is ON, then axis 1, axis 2 and axis 8 move backward.
JBWN (Jog Backward ON)
Expansion
co nd itio n
(A N D · OR)
Input
co nd itio n
(I/O · Flag)
Command
Post
(Output port · Flag)
Command Operand 1 Operand 2
Optional Optional JBW N Axis pattern
Input port ·
Flag
Optional
[Function] While the designated input port or flag (global flag) is OFF, the axis moves backward.
* HOLD is not available for this command.
[Example] JBWF 10000011 25
When input port 25 is OFF, then axis 1, axis 2, and axis 8 move backward.
JBWF (Jog Backward OFF)
Expansion
condition
(A N D · OR)
Input
condition
(I/O · Flag)
Command
Post
(Output port · Flag)
Command Operand 1 Operand 2
Optional Optional JBW F Axis pattern
Input port ·
Flag
Optional