User guide

Page 29-A
Chapter 1. Setting Up
4. Interface List (PNP Sourcing)
Emergency Stop is a b-contact in-
put (normally closed). To release
the emergency stop, short circuit
the jumper post with the jumper pin.
Refer to Supplement 7.
Pin No.3A (Port No.003), and Pin
No.3B (Port No.004) cannot be used
as user inputs.
Connector: Sumitomo 3M 7950-
6500SC or Yamaichi FAP-5001-
1202.
*
*
*
Pin No. Category Port No. Function Cable Color
1A N24 External power 0V 1-Brown
1B
Input
000 External start input 1-Red
2A 001 User input 1-Orange
2B 002 Emergency Stop b contact input *1 1-Yellow
3A 003 System reserve 1-Green
3B 004 System reserve 1-Blue
4A 005 User input 1-Purple
4B 006 User input 1-Gray
5A 007 User input 1-White
5B 008 PRG No. 1 (user input) 1-Black
6A 009 PRG No. 2 (user input) 1-Brown
6B 010 PRG No. 4 (user input) 2-Red
7A 011 PRG No. 8 (user input) 2-Orange
7B 012 PRG No. 10 (user input) 2-Yellow
8A 013 PRG No. 20 (user input) 2-Green
8B 014 PRG No. 40 (user input) 2-Blue
9A 015 User input 2-Purple
9B 016 User input 2-Gray
10A 017 User input 2-White
10B 018 User input 2-Black
11A 019 User input 3-Brown
11B 020 User input 3-Red
12A 021 User input 3-Orange
12B 022 User input 3-Yellow
13A 023 User input 3-Green
13B
Output
300 Emergency stop/Alarm output 3-Blue
14A 301 Ready output 3-Purple
14B 302 User output 3-Gray
15A 303 User output 3-White
15B 304 User output 3-Black
16A 305 User output 4-Brown
16B 306 User output 4-Red
17A 307 User output 4-Orange
17B 308 User output 4-Yellow
18A 309 User output 4-Green
18B 310 User output 4-Blue
19A 311 User output 4-Purple
19B 312 User output 4-Gray
20A 313 User output 4-White
20B 314 User output 4-Black
21A 315 User output 5-Brown
21B 316 User output 5-Red
22A 317 User output 5-Orange
22B 318 User output 5-Yellow
23A 319 User output 5-Green
23B 320 User output 5-Blue
24A 321 User output 5-Purple
24B 322 User output 5-Gray
25A 323 User output 5-White
25B P24 External power +24V 5-Black