Owner manual

311
INTELLIGENT ACTUATOR
Appendix
Appendix
Other Parameters
No Parameter name
Default value
(Reference)
Input range Unit Remarks
21 Manual mode type 0 0 to 5 0: Always enable edit and SIO/PIO start (Initial condition
after connection = With safety speed)
1: Select edit and start (with password) (EU, etc.)
2: Always enable edit and SIO/PIO start (Initial condition
after connection = Without safety speed (cancellation))
(PC software version 1.1.0.7 or later and TP application
version 1.06 or later)
* Referenced by the PC/TP.
22 Control use region 0 0 to 99 0: J, 1: E, 2: EU
23 PSIZ command function type 0 0 to 5 0: Maximum number of point data areas
1: Number of point data used
24 Local variable number for
storing SEL communication
command return code
99
1 to 99
1001 to 1099
25 to
29
(For expansion) 0
30 Option Password 00 0H
0H to
FFFFFFFFH
HOME command option (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
31 Option Password 01 0H
0H to
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
32 Option Password 02 0H
0H to
FFFFFFFFH
Reserved (Change prohibited)
* Change is prohibited unless instructed by the
manufacturer.
33 to
35
(For expansion) 0H
0H to
FFFFFFFFH
36 PC/TP data protect setting
(Program)
0H
0H to
FFFFFFFFH
Bits 0 to 3: Protect type (0: Read/write, 1: Read only,
2: No read/write)
Bits 4 to 7: Protect release method (0: Special
operation)
Bits 8 to 11: Protect range maximum number (1’s place,
BCD)
Bits 12 to 15: Protect range maximum number (10’s
place, BCD)
Bits 16 to 19: Protect range minimum number (1’s place,
BCD)
Bits 20 to 23: Protect range minimum number (10’s
place, BCD)
* Referenced by the PC/TP (PC software version 2.0.0.42
or later and TP application version 1.09 or later)
37 PC/TP data protect setting
(Position)
0H
0H to
FFFFFFFFH
Bits 0 to 3: Protect type (0: Read/write, 1: Read only,
2: No read/write)
Bits 4 to 7: Protect release method (0: Special
operation)
Bits 8 to 11: Protect range maximum number (10’s
place, BCD)
Bits 12 to 15: Protect range maximum number (100’s
place, BCD)
Bits 16 to 19: Protect range maximum number (1000’s
place, BCD)
Bits 20 to 23: Protect range minimum number (10’s
place, BCD)
Bits 24 to 27: Protect range minimum number (1000’s
place, BCD)
* The value in the 1’s place is considered “0” for both the
protect range maximum/minimum numbers.
* Referenced by the PC/TP (PC software version 2.0.0.42
or later and TP application version 1.09 or later)
PC: PC software
TP: Teaching pendant