Description
Action Parameter setting Manipulation/operation
Want to automatically execute
restart (software reset) after the
emergency stop is reset, and start
the auto-start program.
The emergency-stop recovery type
can be set to “Abort
operations/programs (Software reset
when the emergency stop is reset).”
Other parameter No. 10 = 3
I/O parameter No. 33 = 1
After the emergency-stop button is
released, the system will automatically
execute restart (software reset) and
start the auto-start program.
Want to automatically execute error
reset after the emergency stop is
reset, and start the auto-start
program.
The emergency-stop recovery type
can be set to “Abort
operations/programs (Error reset
and auto program start when the
emergency stop is reset).”
Other parameter No. 10 = 4
I/O parameter No. 33 = 1
I/O parameter No. 44 z 1
After the emergency-stop button is
released, the system will automatically
execute error reset and start the auto-
start program.
Setting example) Set the area illustrated
below as zone 1:
Axis 1: Output port No. 316 will turn ON
when the axis enters the area
between 150 and 200 mm.
Axis 2: Output port No. 317 will turn
ON when the axis enters the
area between 75 and 125 mm.
For the output signal to be processed,
the axes must stay for at least 3 msec
in the zone. Duplicate output port
numbers cannot be specified.
Want to output signal when the
actuator enters a specified area
(zone).
A desired actuator zone can be set
for each axis. A desired output port
to turn ON when the axis enters the
zone can be set for each axis. A
maximum of four zones can be set
(zones 1 to 4).
Max. value of zone 1:
Axis-specific parameter No. 86
Min. value of zone 1:
Axis-specific parameter No. 87
Zone 1 output port number:
Axis-specific parameter No. 88
Max. value of zone 2:
Axis-specific parameter No. 89
Min. value of zone 2:
Axis-specific parameter No. 90
Zone 2 output port number:
Axis-specific parameter No. 91
Max. value of zone 3:
Axis-specific parameter No. 92
Min. value of zone 3:
Axis-specific parameter No. 93
Zone 3 output port number:
Axis-specific parameter No. 94
Max. value of zone 4:
Axis-specific parameter No. 95
Min. value of zone 4:
Axis-specific parameter No. 96
Zone 4 output port number:
Axis-specific parameter No. 97
Note: Before shipment, the
parameters are normally set
so that the above output
port numbers can be used.
Before changing a parameter, be sure to read the corresponding section in the List of Parameters.
Axis 2
Axis 1
: Output port No. 316 turns ON.
: Output port No. 317 turns ON.
Axis-specific parameter No. 86
Axis-specific parameter No. 87
Axis-specific parameter No. 88
Axis 1 Axis 2
2
00000
12
5000
150000 75000
3
1
6
3
17
*: Max. and min. values are input in
units of 0.001 mm.
*
*