Owner manual

319
INTELLIGENT ACTUATOR
Appendix
Appendix
~ Error List (MAIN application) (In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
207 Update file name error (IAI protocol) The name of the update program file selected in the update mode is invalid. Select
the correct file and repeat the update procedure from the beginning.
20E Motorola S byte count error The update program file is invalid. Check the file.
20F Update target specification error (Received by the application) The application’s system received an update target specification command. To
update the program, restart the controller and repeat the update procedure from
the beginning.
630 Update system code error (Detected by the application) The update system code is invalid.
631 Update unit code error (Detected by the application) The update unit code is invalid.
632 Update device number error (Detected by the application) The update device number is invalid.
685 I/O function selection physical port number error The I/O port number setting specified for a given I/O function selection is invalid.
Check the settings of I/O parameter Nos. 62 to 65, 76, 77, 283 to 330, etc.
801 SCIF overrun status (IAI protocol reception) Communication failure. Check for noise, connected equipment and communication
setting.
802 SCIF receive ER status (IAI protocol reception) Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting. This error will also occur
when establishing communication with the PC/TP wrongly connected to SIO-CH1
being opened to the user.
803 Receive timeout status (IAI protocol reception) The transfer interval after the first received byte is too long. Possible causes
include disconnected communication cable and error in the connected equipment.
804 SCIF overrun status (SEL reception) Communication failure. Check for noise, connected equipment and communication
setting.
805 SCIF receive ER status (SEL reception) Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.
806 SCIF receive ER status due to other factor (SEL reception) Communication failure. Take the same action specified for error No. 804 or 805.
807 Drive-source cutoff relay ER status The motor-drive power ON status remains ON even when the drive source is cut
off. The drive-source cut-off relay contacts may have been melted.
808 Power OFF status during slave parameter write The power was turned off while writing slave parameters. (This error can be
detected only when a backup battery is used.)
809 Power OFF status during data write to flash ROM The power was turned off while writing data to the flash ROM. (This error can be
detected only when a backup battery is used.)
80A Expanded-SIO overrun status (SEL reception) Communication failure. Check for noise, connected equipment and communication
setting.
80B Expanded-SIO parity ER status (SEL reception) Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.
80C Expanded-SIO framing ER status (SEL reception) Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.
80D Expanded-SIO receive ER status due to other factor (SEL reception) Communication failure. Take the same action specified for error No. 80A, 80B or 80C.
80E Expanded-SIO receive buffer overflow status (SEL reception) The receive buffer overflowed. Excessive data was received from outside.
80F Ethernet control status 1 Ethernet control information (for analysis)
810 Ethernet control status 2 Ethernet control information (for analysis)
811 Maintenance information 1 Maintenance information (for analysis)
812 Maintenance information 2 Maintenance information (for analysis)