Instruction Manual

483
Appendix
(In the panel window, the three digits after ā€œEā€ indicate an error number.)
Error No. Error name Description, action, etc.
435
RC gateway RC axis continuation disable error
The RC axis generated an alarm that disables continuation of operation.
Example:
x A RC position number outside the allowable range was directed.
(RC position data specification mode in RC)
x A speed, acceleration/deceleration or other setting outside the allowable range was
directed.
(RC position data specification mode in X-SEL)
436 RC gateway command alarm error A gateway command generated an alarm.
437 RC axis number error The specified RC axis number is invalid.
438 RC position number error The specified RC position number is invalid.
439 RC gateway operation mode error Operation is not possible in the current RC gateway operation mode.
43A RC gateway status command error Operation is not possible in the current RC gateway status
43B RC axis pattern not-yet-set error The RC axis pattern is not yet set. Issue a RAXS command.
43C RC axis in-use servo OFF error The servo of a RC axis currently in use (under processing) was turned OFF.
43D RC axis multiple use error An attempt was made to acquire the right to use a RC axis already in use.
43E RC axis with error use error An attempt was made to use the RC axis with error.
43F RC axis right-of-use acquisition error The RC axis use management area has no free space.
440 Servo-OFF RC axis use error An attempt was made to use a RC axis whose servo was OFF.
441 RC axis home return incomplete error The RC axis has not yet completed home return.
442 Bad RC axis position complete position error The RC axis position attained upon completion of RC axis positioning is bad.