Table 17. POST error messages (continued)
Error
code/Symptom
Meaning FRU/action
00019501 Processor 1 is not functioning
1. Check VRM and processor LEDs
2. VRM 1, VRM 2
3. Processor 1
4. Processor board
5. System board
00019502 Processor 2 is not functioning
1. Check VRM and processor LEDs
2. VRM 2
3. Processor 2
4. System board
00019701 Processor 1 failed BIST
1. Processor 1
2. System board
00019702 Processor 2 failed BIST
1. Processor 2
2. System board
00180100 No room for PCI option ROM
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180200 No more I/O space available
for PCI adapter
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180300 No more memory (above 1
MB for PCI adapter)
1. Run Configuration/Setup
2. Failing adapter
3. System board
00180400 No more memory (below 1
MB for PCI adapter)
1. Move the failing adapter to slot 1 or 2
2. Run Configuration/Setup
3. Failing adapter
4. System board
00180500 PCI-option ROM checksum
error
1. Remove failing PCI card
2. System board
00180600 PCI built-in self-test failure;
PCI-to PCI-bridge error
1. Run Configuration/Setup
2. Move the failing adapter to slot 1 or 2
3. Failing adapter
4. System board
00180700,
00180800
General PCI error
1. System board
2. PCI card
01295085 ECC checking hardware test
error
Processor
01298001 No update data for processor
1
1. Ensure that all processors are the same stepping level
and cache size.
2. Processor 1