Laptop User Manual
   0031-660  0031-667
0031-660 Partition Manager stopped ...
Explanation:  The Home Node (POE) has stopped in response to a SIGTSTOP (<Ctrl>Z)
signal. The remote nodes have been stopped.
User Response:  To resume the job, issue SIGCONT, or use the shell job control
commands fg or bg.
0031-661 signal_sent = 
number
 not recognized
Explanation:  The indicated signal was recorded as being sent to the remote nodes, but is
not recognized by POE. Execution continues.
User Response:  Probable POE internal error. Gather information about the problem and
follow local site procedures for reporting hardware and software problems.
0031-662 Node 
number
 did not send PROFILE_DONE, sent msgtype
 number
Explanation:  The indicated node did not send the PROFILE_DONE message after
profiling, but sent a message of the indicated type. Message 0031-663 gives the text sent.
User Response:  Consult the explanatory text. If that fails to disclose the problem, gather
information about the problem and follow local site procedures for reporting hardware and
software problems.
0031-663 
string
Explanation:  This is the text of a message received instead of the expected
PROFILE_DONE message.
User Response:  If the text fails to disclose the problem, gather information about the
problem and follow local site procedures for reporting hardware and software problems.
0031-664 Unknown message type 
number
 received
Explanation:  The indicated message type is not known by POE. Execution is terminated.
User Response:  Probably the socket contains a non-structured message, which would be
a stray. If the source of the stray socket message cannot be determined, gather information
about the problem and follow local site procedures for reporting hardware and software
problems.
0031-665 Invalid value for SSM_SINGLE 
number
Explanation:  The indicated value is invalid as a destination for SINGLE I/O mode. The
specification is ignored.
User Response:  Verify that the correct value for SINGLE I/O mode is used.
0031-666 Out of range value for SSM_SINGLE 
number
Explanation:  The indicated value is out of range: less than zero, or greater than the
number of tasks. The specification is ignored.
User Response:  Verify that the correct value for SINGLE I/O mode is used.
0031-667 Invalid value for SSM_UNORDERED 
number
Explanation:  The indicated value is invalid as a specification for UNORDERED I/O mode.
The specification is ignored.
User Response:  Verify that the correct value for I/O mode is used.
  Chapter 4. POE Messages 93










