Laptop User Manual
 0033-1062  0033-2003  
0033-1062 dug: socket read for 
string
 failed Error is
 string
Explanation:  The dug statistics collection program encountered an error reading the socket
connection to the monitor program.
Error Class: The monitor program has probably terminated.
User Response:  Make sure the monitor program is still running and it did not experience a
problem trying to communicate with the dug program.
0033-1063 dug: Monitor program closed the socket connection before
 string
 was read.
Explanation:  The indicated information was not received.
Error Class: The socket was probably closed because the monitor program terminated.
User Response:  Make sure the monitor program is running and did not report any
problems trying to communicate with dug.
0033-1064 dug: Monitor program sent back 
number
 bytes of
 string
 but 
number
 bytes
were expected.
Explanation:  An invalid amount of data was received from the monitor program.
Error Class: The version of the monitor program is incompatible with the version of dug
running.
User Response:  Make sure the right level of dug and the monitor program are running.
0033-1065 dug: socket write of 
string
 to monitor program failed. Error is 
string
Explanation:  The dug statistics collection program encountered an error writing the socket
from either the Performance Monitor or the statistics gathering daemon.
Error Class: The socket write() function failed for the indicated reason.
User Response:  Correct the specified problem.
0033-1066 dug: Only 
number
 of 
number
 bytes of
 string
 could be written on socket
connection to monitor program.
Explanation:  The indicated message was incompletely written to the monitor program
Error Class: The socket was probably closed because the monitor program terminated.
User Response:  Make sure the monitor program is still running and did not errors while
contacting dug
0033-2002 Add: meter name was not specified
Explanation:  The display meter for a manual configuration was not specified.
Error Class: During the manual creation of an event/display pair, the display meter was not
specified.
User Response:  Be sure both the event and the display meter are specified during manual
configuration.
0033-2003 Add: event name was not specified
Explanation:  The event widget for a manual configuration was not specified.
Error Class: During the manual creation of an event/display pair, the meter widget was not
specified.
User Response:  Be sure both the event and the display meter are specified during manual
configuration.
146 IBM PE for AIX V2R4.0: Messages   