Laptop User Manual
   0031-377  0031-402
| 0031-377 Using 
string
 for euidevice.
| Explanation:  Informational message to indicate the messaging passing device being used
| for the batch POE job submitted to LoadLeveler.
| User Response:  None required.
| 0031-378 Ignoring SP_NAME in batch mode
| Explanation:  User has submitted a POE job in batch mode under LoadLeveler and the
| SP_NAME environment variable or associated command-line option was set.
| User Response:  Unset SP_NAME in the environment or remove -spname from the
| arguments line in the LoadLeveler submit file to eliminate the warning, if desired.
| 0031-379 Pool setting ignored when hostfile used
| Explanation:  User has set the MP_RMPOOL environment variable or the -rmpool
| command-line option but a hostfile was found.
| User Response:  Ensure that use of the hostfile was intended.
| 0031-380 LoadLeveler step ID is 
string
| Explanation:  The indicated step ID was assigned by LoadLeveler to the current interactive
| job. It may be useful when using the llq command to determine the job status.
| User Response:  None required.
| 0031-381 Switch clock source requested, but not all tasks on SP
| Explanation:  You or another user set MP_CLOCK_SOURCE=SWITCH, but one or more of
| the tasks were not on SP nodes that have access to the switch. The job is terminated.
| User Response:  If mixed-node execution is acceptable, unset the MP_CLOCK_SOURCE
| environment variable. Otherwise, check that the nodes allocated were all on an SP.
0031-400 Invalid value 
number
 for stdoutmode
Explanation:  User has entered a non-negative value with -stdoutmode or
MP_STDOUTMODE which is greater than or equal to the number of processes requested;
for SINGLE mode, this value must be between 0 and n-1, where n is the number of
processes.
User Response:  Re-run with valid value.
0031-401 Invalid value 
number
 for stdinmode
Explanation:  User has entered a non-negative value with -stdinmode or MP_STDINMODE
which is greater than or equal to the number of processes requested; for SINGLE mode, this
value must be between 0 and
 n
-1, where 
n
 is the number of processes.
User Response:  Re-run with valid value.
0031-402 Using css0 as euidevice for User Space job
Explanation:  User specified command line option -euidevice or used environment variable
MP_EUIDEVICE with a setting of other than css0, which must be used for User Space jobs.
User value has been overridden to allow job to continue.
User Response:  None required.
  Chapter 4. POE Messages 81