User's Manual
Table Of Contents
- Safety information
- Chapter 1. General information
- Chapter 2. Server setup road map
- Chapter 3. Product overview
- Chapter 4. Turning on and turning off the server
- Chapter 5. Configuring the server
- Chapter 6. Installing, removing, or replacing hardware
- Guidelines
- Removing the server cover
- Removing and reinstalling the front bezel
- Installing, removing, or replacing hardware
- Installing or removing a memory module
- Installing or removing a PCI card
- Installing or removing the Ethernet card
- Installing or removing the RAID card
- Installing or removing the ThinkServer 9240-8i RAID 5 Upgrade Key
- Installing or removing the ThinkServer SATA Software RAID 5 Key
- Installing or removing the ThinkServer iKVM Remote Management Module
- Installing or removing the TPM module
- Installing or removing the DIT module
- Installing or replacing an optical drive
- Installing or replacing a hot-swap hard disk drive
- Removing or installing a non-hot-swap hard disk drive
- Replacing the hot-swap hard disk drive backplane
- Replacing the non-hot-swap power supply assembly
- Replacing a hot-swap redundant power supply module
- Replacing the power distribution board and cage assembly
- Replacing the front panel board assembly
- Replacing the front system fan
- Replacing the rear system fan
- Replacing the heat sink and fan assembly
- Replacing the microprocessor
- Replacing the system board battery
- Completing the parts replacement
- Chapter 7. Troubleshooting and diagnostics
- Chapter 8. Getting information, help, and service
- Appendix A. Notices
- Index
Installingorreplacinganopticaldrive
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstandingthe“Safetyinformation”
onpageiii
and“Guidelines”onpage83.
Thistopicprovidesinstructionsonhowtoinstallorreplaceanopticaldrive.
TheEMIintegrityandcoolingoftheserverareprotectedbyhavingalldrivebayscoveredoroccupied.Your
serverhastwoopticaldrivebays.Ifonlyoneopticaldriveisinstalledinthelowerbay,theupperbayis
coveredbyametalEMIshieldonthechassisandalsoaplasticshieldonthefrontbezel.Whenyouinstall
asecondaryopticaldriveoraRDXUSBdrivebundle,savetheremovedEMIshieldfromthechassisand
plasticshieldfromthefrontbezelintheeventthatyoulaterremovethedriveandneedtheshieldsto
coverthedrivebay.
Attention:AnunoccupieddrivebaywithoutanyotherprotectionmightimpacttheEMIintegrityandcooling
oftheserver,whichmightresultinoverheatingorcomponentdamage.TomaintaintheEMIintegrityand
coolingoftheserver,installanewopticaldriveassoonasyouremovethefailingoneortheprotectiveshields.
CAUTION:
Whenlaserproducts(suchasCD-ROMs,DVDdrives,beropticdevices,ortransmitters)are
installed,notethefollowing:
•Donotremovethecovers.Removingthecoversofthelaserproductcouldresultinexposureto
hazardouslaserradiation.Therearenoserviceablepartsinsidethedevice.
•Useofcontrolsoradjustmentsorperformanceofproceduresotherthanthosespeciedherein
mightresultinhazardousradiationexposure.
DANGER
SomelaserproductscontainanembeddedClass3AorClass3Blaserdiode.Notethefollowing.
Laserradiationwhenopen.Donotstareintothebeam,donotviewdirectlywithoptical
instruments,andavoiddirectexposuretothebeam.
Beforeyoubegin,considerthefollowingopticaldriveinstallationrules:
•Theserverhastwoopticaldrivebays.Iftheserverhasonlyoneopticaldriveinstalled,makesurethatthe
opticaldriveisinstalledinthelowerbay(opticaldrivebay1).Theupperbayisforasecondaryoptical
driveoraRDXUSBdrivebundle(serveroption).
•Thefollowingtableprovidesinformationabouttherecommendedpowerconnectorandconnectoron
thesystemboardfortheinstalledopticaldriveorRDXUSBdrivebundle.See“Servercomponents”on
page25forthelocationsoftheopticaldrivebaysand“Systemboardcomponents”onpage42forthe
locationsoftheconnectorsonthesystemboard.
DrivebayDrivePowerconnector
Connectoronthesystemboard
Opticaldrivebay1(lower
bay)
AnopticaldriveinstalledP11
SATA5connector
Anopticaldriveinstalledin
somemodels
P12
SATA4connector Opticaldrivebay2(upper
bay)
ARDXUSBdrivebundle
(serveroption)
P6
Internaldual-portUSB2.0
connector2