User's Manual
v  Check  the  instructions  that  come  with  the  drive  to  see  whether  you  have  to  set 
any  switches  or  jumpers  on  the  drive.  If  you  are  installing  a  SAS  device,  be  sure 
to  set  the  SAS  ID  for  that  device. 
v  Diskette  drives,  tape  drives,  CD  drives,  CD-RW  drives,  and  DVD/CD-RW  combo 
drives  are  examples  of  removable-media  drives.  You  can  install  removable-media 
drives  in  bays  1,  2,  and  3  only. 
v  To  install  a  3.5-in.  drive  in  a  5.25-in.  bay,  you  must  use  the  5.25-in.  conversion 
kit. 
v  Only  a  3.5-in.  device  can  be  installed  in  bay  3. 
v  The  server  supports  only  one  diskette  drive. 
v  The  electromagnetic  interference  (EMI)  integrity  and  cooling  of  the  server  are 
protected  by  having  all  bays  and  PCI,  PCI  Express,  and  PCI-X  slots  covered  or 
occupied.  When  you  install  a  drive  or  PCI,  PCI  Express,  or  PCI-X  adapter,  save 
the  EMC  shield  and  filler  panel  from  the  bay  or  the  PCI,  PCI  Express,  or  PCI-X 
adapter  slot  cover  in  the  event  that  you  later  remove  the  option. 
v  For  a  complete  list  of  supported  options  for  the  server,  see  http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
Installing  a  drive  in  bay  2  or  3 
EMC shield
Filler panel
Drive retainer clip
To  install  a  drive  in  bay  2  or  3,  complete  the  following  steps: 
1.  Read  the  safety  information  that  begins  on  page  v  and  “Installation  guidelines” 
on  page  7. 
2.  Turn  off  the  server  and  peripheral  devices,  and  disconnect  the  power  cords 
and  all  external  cables. 
3.  Remove  the  side  cover  (see  “Removing  the  side  cover”  on  page  10). 
4.  Remove  the  two-piece  bezel  (see  “Removing  the  two-piece  bezel”  on  page 
11). 
Chapter  2.  Installing  options  17