User's Manual
Table  2.  Abbreviated  list  of  POST  error  codes  (continued) 
v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action 
column  until  the  problem  is  solved. 
v  See  the  parts  listing  in  the  Problem  Determination  and  Service  Guide  to  determine 
which  components  are  customer  replaceable  units  (CRU)  and  which  components 
are  field  replaceable  units  (FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must 
be  performed  only  by  a  trained  service  technician. 
Error  code  Description  Action 
175  Service  processor  flash  code 
damaged  or  not  loaded. 
Note:  In  this  case,  the  service 
processor  is  the  optional  Remote 
Supervisor  Adapter  II. 
1.  Update  the  Remote  Supervisor 
Adapter  II  firmware  (see  the 
Problem  Determination  and 
Service  Guide  on  the  IBM 
xSeries  Documentation  CD). 
2.  Replace  the  Remote 
Supervisor  Adapter  II. 
184  Power-on  password  damaged. 
1.  Run  the  Configuration/Setup 
Utility  program,  select  Load 
Default  Settings,  and  save  the 
settings. 
2.  Reseat  the  battery. 
3.  Replace  the  following 
components  one  at  a  time,  in 
the  order  shown,  restarting  the 
server  each  time: 
a.  Battery 
b.  (Trained  service  technician 
only)  System  board 
187  VPD  serial  number  not  set. 
1.  Set  the  serial  number  by 
updating  the  BIOS  code  level 
(see  the  Problem 
Determination  and  Service 
Guide  on  the  IBM  xSeries 
Documentation  CD). 
2.  (Trained  service  technician 
only)  Replace  the  system 
board. 
189  Three  attempts  were  made  to 
access  the  server  with  an  incorrect 
password. 
Restart  the  server  and  enter  the 
administrator  password;  then,  run 
the  Configuration/Setup  Utility 
program  and  change  the  power-on 
password. 
52  xSeries  206m  Types  8485  and  8490:  Installation  Guide