User's Manual
Table 3-2  (Page  6  of  9).  Firmware Error Codes.
Error Code Description Action/
Possible Failing FRU
 xxx=000 Initialization failed, device test failed
  001 init-nvram invoked, ALL of NVRAM
initialized 
  002 init-nvram invoked, GE area preserved,
remaining areas initialized.
  011 Data corruption detected, ALL of
NVRAM initialized
  012 Data corruption detected, GE area
preserved, remaining areas initialized 
  100 NVRAM data validation check failed. Turn off, turn on system unit and retry
the operation.
25AA0xxx  EEPROM  Note:  Ensure that the EEPROM
Security jumper is in the correct
position if doing a
priviliged-access password
install.
Consult the system's User's Guide for
jumper location and position.
Retry the operation.
If retries do not solve the problem,
replace the system board.
 xxx=000 Unable to unlock EEPROM
  001 Read-Recv error
  002 Read-Trans error
  003 Write-enable error
  004 Write-recv error
  005 Write-disable error
  006 Write-Trans error
  007 Unable to lock EEPROM
25Cyyxxx  Memory 
    Chapter 3. Error Code to FRU Index for Model 140 and Model 240 3-9