SMI message code Suggested action
1503 (SERR: Received Target Abort)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1504 (SERR: Device Signaled SERR)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1505 (PERR: Master Read parity error)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1506 (PERR: Master Write parity error)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1507 (PERR: Slave signaled parity error)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1509 (SERR / PERR Detected on PCI
bus)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1510 (SERR: Signaled Target Abort)
1. Check Operating System event log.
2. Run adapter card diagnostics, if available.
3. Adapter.
4. PCI switch card assembly.
5. I/O board.
1511 (MCA: Recoverable Error Detected)
v Information only; run system diagnostic programs when multiple
entries accumulate.
1512 (MCA: Unrecoverable Error
Detected)
1. Run system diagnostic programs.
2. Microprocessor x (where x = indicated microprocessor).
3. VRM.
4. Microprocessor tray assembly.
Chapter 6. Symptom-to-FRU index 107