Unit Door Station User's Manual IHX-C1201 Series V1.1.
Welcome Thank you for purchasing our product! This quick start guide is designed to be a reference tool for your system.
Table of Contents 1 Overview ................................................................................................. ......... 1 2 Basic Functions............................................................................................... . 6 2.1 Call MGT center .................................................................................................. 6 2.2 Call Users ............................................................................................................ 6 2.2.
1 Overview Connect the device to the power, the system boots up properly. After one minute, the screen turns on and the boot-up completes, system goes to the normal working interface. The front panel is shown as in Figure 1- 1 and Figure 1- 2. Figure 1- 1 Please refer to the following sheet for detailed information. 1 SN Name Function 1 Logo Decoration logo. 2 Photo Sensor 3 Compensation Light 4 Microphone It can detect the environment light. It is a compensation light option.
1. Button. a) Backspace function. It is to delete the previous symbol. b) Hang up function. It is to hang up the call. 2. Number button. Input the number 0 to 9. 3. 5 Key Panel button. When you are using the password to open the door. Press this button once to begin input. After you input the password, please press it again to complete the operation. 4. Call button. After you input the room number, press it to begin a dial up. 5. Call management (MGT) center button.
to confirm. 9 3 Camera It is to monitor the video of the door.
Figure 1- 2 Please refer to the following sheet for detailed information. SN Name Function 1 Logo Printed logo. 2 Microphone Audio input 3 Compensation Light It can compensate the camera light in the low illumination environments. 4 5 4 Approaching Induction Speaker It can detect approaching body.
1. Button. a) Backspace function. It is to delete the previous symbol. b) Hang up function. It is to hang up the call. 2. Number button. Input the number 0 to 9. 3. 6 Key Panel button. When you are using the password to open the door. Press this button once to begin input. After you input the password, please press it again to complete the operation. 4. Call button. After you input the room number, press it to begin a dial up. 5. Call MGT center button. Press it to call the MGT center directly.
2 Basic Functions 2.1 Call MGT center In the standby status ( Figure 1- 1, Figure 1- 2), press or button, this IHX will call the MGT center. The video door phone begins when the MGT Port picks up. During the whole process, you can press the button or to end current dialogue and return to the standby interface. 2.2 Call Users 2.2.1 Call Status In the standby status, input the room number and then press the button or ,you can generate a call to the IHD of the user.
2.4 Unlock Function 2.4.1 Unlock During the Dial Process During the dial process, the MGT Port or the IHD can open the door lock of the device remotely. System returns to the standby interface after phone hangs up or the countdown is complete. 2.4.2 Unlock During the Communication During the communication process, the MGT Port or the IHD can open the door lock of the device remotely. System returns to the standby interface after phone hangs up or the countdown is complete. 2.4.
2.6 Access Control (A&C) Function The device can connect 1-channel door sensor input. It can be used to detect door status. There is 1-channel door on-off button to open/close the door. It has 2-channel control output. There are two modes: NO/NC. It can also be used for other general controls. Please refer to later sections for detailed information. 2.7 Vandal Proof Function There is 1-chahnel vandal proof button. System can generate an alarm once it is removed from the wall.
Figure 3- 1 Please refer to the following sheet for detailed information. SN Name 1 System Settings 2 Info Search 3 Status Statistics 4 Logout Function You can set IHX-C1202B device parameter and network info. You can search IHX-C1202B call history. You can perform statistics of IHD status under IHX-C1202B. You can control reboot of IHX-C1202B and shutdown of WEB server. 3.2 Basic Functions 3.2.1 Login Interface Input IHX IP address in address field of IE Explorer as in Figure 3- 2.
Figure 3- 2 You must input username and password in order to login WEB main interface. Default username: admin Default password: admin. After you login, you will see 4 major settings: system, info search, status statistics, and Logout. 3.2.2 System Settings System settings includes: local, IHD management, networking, network and password change. 3.2.2.1 Local Setting The following is the instruction for major settings: 1. Frame: For NTSC standard, please select 30 frame/s.
Figure 3- 3 3.2.2.2 Access Control Management Click on local setting and then click on access control management. You may change password here and please keep in mind that the initial password is 123456. To unlock door, please input #123456#. You also can set unlock interval and duration. FTP address: FTP address is used to store snapshot taken at IHX when someone swipes card. User can login FTP to view those photos.
Figure 3- 4 3.2.2.3 System Time Click on local setting and then click on system time. You may set time in the following interface as in Figure 3- 5. You may also synchronize system time with your local PC.
3.2.3 IHD Management IHD management mainly includes add digital/analog IHD, delete IHD and edit IHD user. 3.2.3.1 Digital IHD Management In digital IHD management interface, check box display resident info enable to display successfully configured IHD info as shown in Figure 3- 6. Click on add button at the left lower corner, and input user name and IHD number. Please be notified that only IHD number is required for operation as default. Figure 3- 6 3.2.3.
Figure 3- 7 LAN Setting Default setting is enough if you just want networking between IHX and IHD, but if you want to set MGT center, you need to change default settings to be identical with MGT center info. You also need to check box register to the MGT center. If you successfully set MGT center, you may call MGT center by pressing call MGT center button at lower left corner on IHX. Please see Figure 3- 8.
In network setup interface, you can set IP parameter, IP address, subnet mask and default gateway of IHX as shown in Figure 3- 9. After you change IP address, WEB interface will reboot and you will see a new IP address interface. Figure 3- 9 Change Password In password change interface, you can change WEB login password of IHX. You must input old password, new password and confirm new password. Click on OK button to save as shown in Figure 3- 10.
Figure 3- 11 Status Statistics Click on status statistics and then click on IHD status. Here you can view connection status of IHD as shown in Figure 3- 12. Figure 3- 12 Logout Click on Logout. Here you may select either to reboot device or Logout system as shown in Figure 3- 13 and Figure 3- 14.
Figure 3- 13 Figure 3- 14 4 Specifications Model IHX-C1201 OS Main Processor Embedded micro processor OS Embedded LINUX OS Video Video Compression Standard H.264 Input/Approaching Induction 1.
Output Built-in speaker Bidirectional Talk Support dual-way bidirectional talk Display LCD Dimensions 3-inch STN 3-inch screen screen Resolution Operation Mode 128*64 128*64 Input Digital keyboard Touch keyboard Card Built-in IC card induction reader Approaching Induction Body Approaching Not applicable 1 meter Alarm Vandal proof Access Control Support NO Output Support NC Output Support Door on/off Button Support Door Status Detect Support Network Ethernet 10M/100Mbps Self-a
Figure 5- 1 IHX-C1201 rear structure Please refer to the following sheet for detailed information. SN Port Name 19 1 Network Port 2 Access Control Input Port 3 Analog Signal Port (IHX-C1201 only) Function Connect to the RJ45 port. Connect to signal from the door sensor, door on/off signal. Connect to the analog signal of the distributor.
4 Vandal Proof Alarm Button 5 RS422 Port (Reserved) 6 Power Port It can generate an alarm when there is a vandal operation. Connect to RS422 or RS485 Communication Device. Connect to 12V DC. Control NO/NC of door lock.
Figure 5- 2 IHX-C1202B rear structure Please refer to the following sheet for detailed information. SN Port Name Function 1 2 3 21 Vandal Proof Button Network Port Access Control Port Alarm It can generate an alarm when there is a vandal operation. Connect to the RJ45 port. Input Connect to signal from the door sensor, door on/off signal.
4 5 6 Power Port Access Output Connect to 12V DC power. Open or close the NO/NC lock. Control Port Analog Signal Port Connect to the analog signal of the distributor. Connect to RS422 or RS484 communication device. 7 RS485 Port 6 Installation Please refer to the following sheet for detailed installation information. Please see Figure 6- 1 and Figure 6- 2 IHX-C1202B installation guide.
Figure 6- 1 IHX-C1201 installation guide 23
Figure 6- 2 IHX-C1202B installation guide 7 FAQ Q: I cannot boot up the device, or I can see the LCD is black. A: Please check your power cable connection. Please reboot it again. Q: I cannot call. A: Please check your network connection. Q: I cannot reach the person I want to contact. What shall I do? A: It may be the network error. Please check the network cable connection between the host and the extension device. Q: The number I dial does not exist.
Q: System says the IC card number is invalid when I swipe the card. What shall I do? A: The card status is abnormal. Please contact your administrator for help. Q: System says the IC card number is wrong. What shall I do? A: It means current card does not have the authority. Please contact your administrator for help. Q: I have some problems, I am not so sure or I can not fix. A: Please contact your local retailer for help. Note: This manual is for reference only.