Intelligent Speed Dome Installation Manual Version 1.0.
Table of Contents 1 INTELLIGENT SPEED DOME INSTALLATION.................................................. 1 1.1 Installation Environments ..................................................................................................................... 1 1.2 Check installation space and installation location intension ........................................................... 1 1.3 About cable.........................................................................................................
4 WALL MOUNT BRACKET INSTALLATION...................................................... 10 4.1 Component Installation ....................................................................................................................... 10 4.2 Wall Mount Installation Steps ............................................................................................................ 10 4.2.1 Installation Environments.......................................................................................
9 APPENDIX Ⅳ12V AC WIRE GAUGE AND TRANSMISSION DISTANCE RELATIONSHIP SHEET .......................................................................................... 20 10 APPENDIX V WIRE GAUGE REFERENCE SHEET ........................................
Welcome Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product! iv
Important Safeguards and Warnings Safety Measures 1. Qualified Engineer Needed z The installation engineer or maintenance engineer shall have corresponding CCTV system installation certificate or maintenance qualification certificate. z The installation engineer or maintenance engineer shall have qualification certificate for work at height.
. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair. Note 1. Safety Transportation z z z Heavy stress, violent vibration or water splash are not allowed during transportation, storage and installation. This series product must use split type package during the transportation.
z Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake. z Do not allow the plastic or rubber material to touch the shell for a long time. It may result in paint flake.
1 INTELLIGENT SPEED DOME INSTALLATION 1.1 Installation Environments Basic Requirement z z All installation and operation here should conform to your local electrical safety codes. Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet your requirement. If there is special requirement, please contact your local retailer for more information.
2 SETUP BEFORE INSTALLATION 2.1 Check Accessories Before the installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are included. 2.2 Open Device This section is for intelligent analog speed dome, intelligent network speed dome, and intelligent tracking speed dome. Remove the package and then take out the device. Open the transparent cover and take out the packing material EPE around the speed dome drive.
2.4 Dial Switch Setup (For Analog Speed Dome Only) The following operation is based on the ceiling mount speed dome. Here we are going to set speed dome address, baud rate and etc. There are two dial switches on the PTZ for you to set address, baud rate and etc. See Figure 2-2. Figure 2-2 2.4.1 Dial Switch Buttons Before you control speed dome, please set the speed dome address, baud rate, parity. Otherwise, you can not control the device! See Figure 2-3.
Figure 2-3 There are two dial switch buttons on the PTZ. You can use them to set speed dome address, baud rate, and parity respectively. It is 1 when you set the button as ON. For the protocol dial switch, you can refer to the following sheet. 1 is the lowest bit and the 8 is the highest bit. Please note the intelligent speed dome can automatically recognize the industrial standard protocol, PELCO-D. PELCO-P. Usually you do not need to set the protocol. 2.4.
ON ON NONE 2.4.3 Address The address interface is shown as in Figure 2-5. Figure 2-5 The encode mode adopts binary system. 1 to 8 is valid bit. The highest address bit is 255. You can refer to the following sheet for more information.
If you want to connect the 120Ω resistance, please remove the jumper from the pin 2 and pin 3 and connect to pin 1 and pin 2. Now the 120Ω is connected to the circuit. See Figure 2-8.
3 CEILING MOUNT 3.1 Installation Components The ceiling mount installation component is shown as in Figure 3-1. Figure 3-1 3.2 Ceiling Mount Installation Steps 3.2.1 Installation Environments The ceiling mount speed dome can be installed in the hard construction wall in the indoor environments. Before the installation, please make sure: z The wall is thick enough to install the expansion bolt. z The ceiling can at least sustain the 8x weight of the speed dome, bracket and the accessories. 3.2.
3) In Figure 3-2, pull the cable according to your cable exit mode. And then use four screws (working with insulated sleeve) to secure the pedestal of ceiling mount speed dome on the ceiling. Turn the screws to the plastic expansion bolts. Figure 3-2 4) In Figure 3-3, line up the arrow symbol on the speed dome external enclosure to the bar symbol of the pedestal. Use three screws (provided) to secure the external enclosure on the pedestal and fix firmly.
3.2.3 Cable Connection The step listed below is for ceiling, in-ceiling or wall mount series product. Please connect the power cable, video output cable, RS485 control cable, alarm input/output pin of the intelligent speed dome composite cable according to your actual requirements. Pleas use insulation tape to seal the cable connection ports to do proper waterproof work. Note The video port is covered the heat shrink tube of high shrinking ratio.
4 WALL MOUNT BRACKET INSTALLATION 4.1 Component Installation The wall mount bracket and outdoor speed dome is shown as in Figure 4-1. Figure 4-1 4.2 Wall Mount Installation Steps 4.2.1 Installation Environments The wall mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments. Before the installation, please make sure: z The wall is thick enough to install the expansion bolt.
Figure 4-2 3) Dig holes in the wall according to the installation holes at the bottom of the wall mount bracket. Please make sure the cable exit of the bracket is facing the round hole of the wall. Insert expansion bolts (not provided) to the holes you just dug. Connect the composition cable and then pull it through the hole in the wall. Use four hex screws and flat washer to secure the bracket on the wall of the expansion bolts. See Figure 4-3.
Now the installation is complete. See Figure 4-4.
5 IN-CEILING MOUNT BRACKET INSTALLATION 5.1 Component Installation The in-ceiling bracket and speed dome body is shown as below. See Figure 5-1. Figure 5-1 5.2 Installation 5.2.1 Installation Requirements The in-ceiling mount speed dome can be installed in the hard construction wall in the indoor environments. Before the installation, please make sure: z The ceiling thickness ranges from 10-40mm. z The ceiling can at least sustain the 8x weight of the speed dome, bracket and the accessories. 5.2.
Figure 5-2 Connect the composition cable and then put the cable to the hole you just dug. Push the inceiling bracket and dome body to the hole you just dug. Turn the fastening screw to secure the hanging board. See Figure 5-3. Figure 5-3 In Figure 5-4, use three screws to secure the in-ceiling decoration enclosure component to the in-ceiling bracket components and fix them firmly. See Figure 5-5.
Figure 5-4 After the installation, the interface is shown as in Figure 5-5.
6 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 4000W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment.
7 APPENDIX Ⅱ ABOUT RS485 BUS 7.1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 7.2 RS485 Bus Transmission Distance When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
Figure 7-2 7.4 RS485 Bus FAQ Phenomenon Speed dome can run selfdiagnosis but I can not control it.
8 APPENDIX Ⅲ THE 24V AC WIRE GAUGE AND TRANSMISSION DISTANCE RELATIONSHIP SHEET It is the recommended transmission distance when the cable diameter is fixed and the 24V AC power consumption is below 10%. For the AC device, the max permission voltage power consumption is 10%. For example, when a device of rated power 20W installed from the transformer 141 inches (42m), then the min cable diameter is 0.8000mm.
9 APPENDIX Ⅳ12V AC WIRE GAUGE AND TRANSMISSION DISTANCE RELATIONSHIP SHEET The recommended max transmission distance is under the following environments: The wire diameter is fixed and the DC 12V power voltage loss rate is below 10%. For the device of DC power supplying, the max allowed voltage loss rate is 10%. Feet (m) mm 0.8000 1.000 1.250 2.
10APPENDIX V WIRE GAUGE REFERENCE SHEET Metric bare wire diameter (mm) 0.050 0.060 0.070 0.080 0.090 0.100 0.110 0.130 0.140 0.160 0.180 0.200 0.230 0.250 0.290 0.330 0.350 0.400 0.450 0.560 0.600 0.710 0.750 0.800 0.900 1.000 1.250 1.500 2.000 2.500 3.000 AWG SWG 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 16 15 12 47 46 45 44 43 42 41 39 37 35 33 31 30 29 28 24 23 22 21 20 19 18 14 Bare wire cross section (mm2) 0.00196 0.00283 0.00385 0.00503 0.00636 0.00785 0.
• If there is any uncertainty or controversy, please refer to the final explanation of us. • Please visit our website or contact your local service engineer for more information.