HD Vandal Proof IP Dome Camera User’s Manual Version 3.0.
Welcome Thank you for purchasing our IP camera! This user’s manual is designed to be a reference tool for your system.
Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 12V DC or 24V AC in the IEC60950-1. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device. Finally use the dry cloth to clean the device. Please put the dustproof cap to protect the CCD (CMOS) component when you do not use the camera. 7. Accessories Be sure to use all the accessories recommended by manufacturer. Before installation, please open the package and check all the components are included.
Table of Contents 1 General Introduction .................................................................................................................. 1 1.1 Overview........................................................................................................................ 1 1.2 Features......................................................................................................................... 1 1.3 Specifications............................................................
FAQ ...............................................................................................................................................26 Appendix Toxic or Hazardous Materials or Elements ...............................................................
1 General Introduction 1.1 Overview This series IP camera integrates the traditional camera and network video technology. It adopts audio and video data collection, transmission together. It can connect to the network directly without any auxiliary device. This series IPC uses standard H.264 video compression technology and G.711a audio compression technology, which maximally guarantee the audio and video quality.
Support system resource information and running status real-time display. Day/Night mode auto switch (ICR switch). Built-in IR light. Support IR night vision (For ICIP3000DV-IR Series only). Backlight compensation: screen auto split to realize backlight compensation to adjust the bright. Support electronic shutter and gain setup. Support video watermark function to avoid vicious video modification. 1.3 Specifications 1.3.
Audio Snapshot Privacy Mask Video Setup Video Information Lens Lens Interface Audio Input Audio Output Bidirectional Talk Input Audio Bit Rate Audio Compression Standard Vide o Motion Detect Video Loss BackupandRecord Alarm Input Record Priority Local Storage Wire Network Max 1f/s snapshot. File extension name is JPEG. Supports max 4 privacy mask zones Support parameter setup such as bright, contrast. Channel title, time title, motion detect, privacy mask. 3.3~12mm@F1.4 CS.
Default setup Function Setup Type Item ICIP3000DV-IR Series Conditions Video Brightness 50 Contrast 50 Hue 50 Saturation 50 Gain mode Auto Gain limit 80 Exposure mode Auto Auto iris Enable Scene mode Auto Day/night mode Auto BLC Off Flip Video stream Disable bit Bit stream type Encode mode Resolution Main stream Extra stream General H.
Default setup Function Setup Type Item ICIP3000DV-IR Series Bit rate I frame interval Snap type Snapshot Overlay Path Aud io Main stream Sub(Extra) stream Network setup TCP/IP Connection Image size Series 640 50 General snap 1080P (1920*1080) Quality Better Interval 7s Privacy mask Enable Channel title Enable Time title Enable Snapshot path C:\PictureDownload Record path C:\RecordDownload Enable Enable Encode mode G.
Default setup Function Setup Type Item ICIP3000DV-IR Series PPPoE DDNS IP filter SMTP(email) UPnP SNMP Series UDP port 37778 HTTP port 80 RTSP port 554 Enable Disable User name N/A Password N/A Server type Disable ,CN99 DDNS Server IP none Port Domain name 80 User name none Password Update period N/A Trusted sites Disable SMTP server none Port 25 Anonymity Disable User name anonymity Password N/A Sender Authenticatio n (Encrypt mode) Title (Subject) Main Receiver
Default setup Function Setup Type Item ICIP3000DV-IR Series Enable Enable Server name “Device name+SN”. Depends on the device. Multicast address 239.255.42.42 Port 36666 Enable Disable SN 1 Server IP 0.0.0.
Default setup Function Setup Type Item ICIP3000DV-IR Series Relay (Alarm) activation Alarm setup Activation Disable Address 0 Snapshot Disable Enable Disable Relay input Alarm1 Anti-dither 5s Sensor type Record channel NO Record delay Relay (Alarm) output Relay (Alarm) delay 10s Send email Disable PTZ Disable Activation N/A Address 0 Series Enable Enable 10s Snapshot Disable Relay (Alarm) 1 output No SD card Abnormity Capacity warning errorS D Enable Relay (Alarm) output
Default setup Function Setup Type Item ICIP3000DV-IR Series Disconnectio n I P confli ct Storage management FT P Destination(Storag e) Networ storag k e Conditions control) (Record Relay output delay 10s Send email Disable Enable Disable Record Enable Record delay Relay (Alarm) output Relay output delay 10s Enable Disable Record Enable Record delay Relay (Alarm) output Relay output delay FTP enable 10s Disable Server IP N/A Port 21 User name anonymity Password Remote storage
Default setup Function Setup Type Item ICIP3000DV-IR Series setupLo cal Date and time General setup Record mode Auto Device name Device factory SN Language Video standard English Date format Y-M-D Time format 24H Time zone GMT+08:00 Current time Sync PC DST Disable DTS type Week 00:00:00 of the first Sunday of the month 00:00:00 of the second Monday of the month Start time End time System management PTZ setup Auto maintenance Series NTSC Synchronize with NTP Disable NTP server
2 Structure 2.1 Multiple-function Combination Cable You can refer to the following figure for multiple-function combination cable information. See Figure 2-1. Figure 2-1 Please refer to the following sheet for detailed information. Port Name Function Connection VIDEO OUT Video port output BNC AUDIO IN Audio port input RCA AUDIO OUT Audio port output RCA 12V DC/AC24V Power port I/O I/O cable port LAN Network port input / Note Output analog video signal.
Port Name Cable Color Name Note Grey ALARM_IN2 Alarm input port 2. It is to receive the on-off signal from the external alarm source. Alarm output port. It is to output the alarm signal to the alarm device. White ALARM_NO NO: normal open alarm output port. It works with the ALARM_COM port. Blue RESET It is to restore factory default setup.
Figure 2-3 2.3 Bidirectional talk 2.3.1 Device Connection Before the operation, connect the active pickup to the audio input port of the device. Connect the active speaker to the audio output port of the device. Please make sure the client-end device has the audio input and output function. For example, you need to connect the microphone and then earphone to the PC if you want to implement the bidirectional talk function. 2.3.
Figure 2-4 14
3 Installation This series IPC can be put on the table to realize surveillance. Or you can use the bracket or the in-ceiling installation to realize the hang function. Please refer to the steps listed below. 3.1 Device Installation Step 1 Use the inner hexagonal wrench (provided) to loose the three inner hexagon screws in the dome cover and then open the cover.
Step 3 Draw out the cable exit and four screw holes in the installation position according to the device pedestal. Dig the four plastic expansion bolt holes and cable exit. Insert the four plastic expansion bolts into the screw holes Step 4 Adjust the camera pedestal to the proper position and then draw the cable through the cable exit you just dug in the ceiling (wall). Line up the four screw holes in the device pedestal to the four plastic expansion bolt holes in the installation position.
e): Put the enclose back after you completed the setup. With IR light Without IR light Figure 3-4 Please note, the screws in the following figure are the optical adjustment component. Please make sure it is outward and do not allow it to touch the X-Y-Z axis module. See Figure 3-5 Figure 3-5 Step 7 Put the dome cover back and then put the three inner hexagon screws into the holes of the device. Use the inner hexagonal wrench to fasten these three screws.
3.2 SD Card Installation Important Before you install the SD card, please unplug he power cable to shut down the device! First, please refer to the step1 in the chapter 3.1 to open the device. Second, please adjust the proper position to install the SD card. Last, please refer to the step 7 in the chapter 3.1 to complete the installation. See Figure 3-7. With IR light Without IR light Figure 3-7 3.3 Lens Adjustment Step 1 Slightly loose the screw B manually and then turn the screw B slowly.
With IR light Without IR light Figure 3-8 19
4 Quick Configuration Tool 4.1 Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. 4.2 Operation Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 4-1. In the device list interface, you can view device IP address, port number, subnet mask, default gateway, MAC address and etc.
Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 4-3. Figure 4-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set. In the configuration tool search interface (Figure 4-1), please select a device IP address and then double click it to open the login interface. Or you can select an IP address and then click the Login button to go to the login interface.
Figure 4-5 22
5 Web Operation This series IPC product support the Web access and management via PC. Web includes several modules includes monitor channel preview, PTZ control, system configuration, alarm and etc. IP camera factory default setup: IP address: 192.168.1.108. User name: admin Password: admin 5.1 Network Connection Please follow the steps listed below for network connection. Make sure the IPC has connected to the network properly.
Figure 5-2 If it is your first time to login in, system pops up warning information to ask you whether install control webrec.cab or not after you logged in for one minute. Please click OK button, system can automatically install the control. When system is upgrading, it can overwrite the previous Web too. If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable the control download. Or you can lower the IE security level. See Figure 5-3.
Figure 5-4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction.
6 FAQ Bug I can not boot up the device. SD card times Please click RESET button for at least five seconds to restore factory default setup. write Do not set the SD card as the storage media to storage the schedule record file. It may damage the SD card duration. I can not use the disk as the storage media. When disk information is shown as hibernation or capacity is 0, please format it first (Via Web).
Appendix Toxic or Hazardous Materials or Elements Component Name Toxic or Hazardous Materials or Elements Pb Hg Cd Cr VI PBB PBDE Circuit Board Component ○ ○ ○ ○ ○ ○ Device Construction Material ○ ○ ○ ○ ○ ○ Wire and Cable ○ ○ ○ ○ ○ ○ Packing Components ○ ○ ○ ○ ○ ○ Accessories ○ ○ ○ ○ ○ ○ O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard.