IHD7210 VDP User’s Manual V.1.
Table of Contents Caution 3 Chapter 1 General Introduction .................................................................................. 3 1.1 Product Appearance ............................................................................................ 3 1.2 Buttons ................................................................................................................ 4 1.3 Indicator..............................................................................................................
Caution All installation and operation here should conform to your local electrical safety codes. We assume no liability or responsibility for all fires or electrical shock caused by improper handling or installation. We are not liable for any problems caused by unauthorized modifications or attempted repair. The device should be installed in a cool, dry place away from direct sunlight, inflammable, explosive substances, etc. Chapter 1 General Introduction 1.
1.2 Buttons Figure 1- 2 The buttons are illustrated in Figure 1- 2. Their descriptions are shown in Chart 1- 1. Button locations may vary, but the function of the buttons with same label is identical. No. Name Description 1 SOS Emergency calling management center 2 Arm or Menu Press the button to enter arm/disarm interface or return to main menu. 3 Call Press the button when being called, you can answer the call; press the button during a call, you can hang it up.
Chapter 2 Basic Function Introduction 2.1 Main Menu This product main menu consists of four menus, as video bidirectional talk, alarm, info search, system setup: in main menu, upper-left corner is network connection, main door station connection, DND setup and other status info, middle portion is current time(month, day, week and time), lower-right corner is arm/disarm button which allows selection between arm and disarm. 2.2 Video Talk Bidirectional Talk Function 2.2.
may switch to next video from door station since the device support 8-ch videos at the same time with 1 large window and 7 small windows. You may turn it off by pressing monitor button again and VDP will return to standby interface. 2.2.5 Call Record Function Under “video bidirectional talk” status click “call record”, you will see missed calls, received calls, and dialed calls, which include information of caller and time. You may go to different pages of records.
When alarm happens in any protection zone, there will be a 15s beep locally with alarm interface pops up. 2.3.3 Mode Setup Alarm of this product consists of away mode, in mode, sleep mode, and user mode. You may set each mode to on/off separately for each protection zone. Default setup are as follows: Away mode: 1-8 channels all on; In mode: 1-3 channels on, others off; Sleep mode: 1-5 channels on, others off; User mode: all off. 2.
normal status. You may exit anytime during the 45s by pressing unlock button. 2.5.2 Project Setup This setup includes device info, network terminal, restore default settings. 1. Device info: includes room number, IP address, subnet mask, default gateway, MAC address, and version info. 2. Network terminal: includes door station name, device type, door station ID (manufacture use only), door station IP address, network port number, working status.
Chapter 3 Technical Specifications Technical specifications are as follows; please see Chart 3- 1. Model IHD7210 System Main Processor Built-in microcontroller Operating System Built-in LINUX system Video Video Compression Standard H.
Figure 4- 1 Please see Chart 4- 1. No. Name Description 1 Alarm Interface 8-ch alarm, please see tag for details 2 Communication Port May directly connect to network cable or via corridor exchanger 3 Handset Interface Only models with earphone have this interface. 4 Power Interface Connect to 2-pin with 3.
Chapter 5 Device Installation Guide Figure 5- 1 (1) Try to avoid exposing the VDP to harsh environments, such as condensation, high temperature, grease, dust, corrosion, direct sunlight, etc. (2) If there is abnormality after you plug in, you should unplug it immediately and unplug the device from power supply. You may plug in the device to power supply after troubleshooting. (3) Device installation and test must be done by professional staff.
Note: This manual is for reference only. Slight difference may be found in user interface. All the designs and software here are subject to change without prior written notice. All trademarks and registered trademarks are the properties of their respective owners. If there is any uncertainty or controversy, please refer to the final explanation of us. Please visit our website or contact your local service engineer for more information.