User Manual

52
Parameter
Function
Working Period
Here you can set arm/disarm period. Click on set button to
open period setup menu.
There are six periods every day for setup and you must check
box in front of each period to enable it.
Anti-dither
System only memorizes one event during the anti-dither period.
The value ranges from 0s to 100s.
Area
Here you can set motion detection region and its sensitivity and
area. (The higher the sensitivity is, the easier to trigger motion
detect; the smaller the area, the easier to trigger motion detect.)
The default covers all regions. You must click on save before
enabling your setup.
Record
Check it and so when alarm occurs, system will auto record.
You shall set record period in Storage>Schedule and select
auto record in record control interface.
Record Delay
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Relay out
Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding alarm
device when alarm occurs.
Alarm Delay
System can delay the alarm output for specified time after alarm
ended. The value ranges from 10s to 300s.
Send Email
If you enabled this function, System can send out email to alert you
when alarm occurs and ends. User can set email address in
Network>SMTP.
PTZ
Here you can set PTZ movement when alarm occurs. Such
as go to preset x when there is an alarm.
The event type includes: preset, tour and pattern.
Snapshot
You need to check the box here so that system can backup motion
detection snapshot file.
See Figure 5-31.