5.3.2 Alarm
Please note some series products do not support this function.
5.3.2.1 Alarm activation
The alarm activation interface is shown as in Figure 5-35.
Figure 5-35
Please refer to the following sheet for detailed information.
Parameter
Function
Enable
After enabled, relay activation will work.
Alarm input
The default is alarm 1 and for some devices may be alarm 2.
Working
period
This function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to
enable corresponding period.
Select date. If you do not select, current setup applies to
today only. You can select all week column to apply to the
whole week.
Click OK button, system goes back to motion detection
interface; please click save button to exit.
Anti-dither
System only memorizes one event during the anti-dither period.
The value ranges from 0s to 100s.
Sensor type
There are two options: NO/NC.
Flash
After enabled, when alarm occurs, the system will turn on flash.
Note: Only some series support flash.