Technical Manual

GEM-MFI SERIES For the Installer
Page 4
Bin Application
The GEM Series are designed to fit the following Ice-O-Matic Bins
B42, using Bin Top KBT 24 (Note: 21 inch wide cabinet ONLY)
B25, B40 B55 using Bin Top KBT 19.
B100-B120 using Bin Top KBT 23 (one unit) or KBT 22 (two units).
B150, B170 Not designed for GEM-MFI Series.
Dispenser Application
The GEM Series can be placed on and used with certain ice and beverage dispensers. Kits are required
for
proper operation. The MFI Series is not approved
for dispenser applications.
IOM Gem Accessory List
Dispenser GEM0450 GEM0650 GEM0956
ICE-O-Matic IOD150 KBT15022, KGEMDIV KBT15022, KGEMDIV KBT15022, KGEMDIV
ICE-O-Matic IOD200 or IOD250 KBT25022_KGEMDIV+KGEMBIOD KBT25022_KGEMDIV+KGEMBIOD KBT25022_KGEMDIV+KGEMBIOD,
Cornelius ED or DF150 KBT15022+R629088514* KBT15022+ R629088514* KBT15022+R629088514*
Cornelius ED or DF200 KBT25022+KGEM200 KBT25022+ KGEM200 KBT25022+ KGEM200
Cornelius ED or DF250 KBT25022+ KGEM250 KBT25022+ KGEM250 KBT25022+ KGEM250
Cornelius ED300 KGEM300+629087966* KGEM300+629087966* KGEM300+629087966*
Cornelius Flavor Fusion KDIL-N-CFF+62988681 Black* KDIL-N-CFF+62988681 Black* KDIL-N-CFF+62988681 Black*
Lancer (Must have N in the
part number) 30 Inch 4500
Model
KDIL-N-L and Lancer Part Number 82-
3491
KDIL-N-L and Lancer Part Number
82-3491
KDIL-N-L and Lancer Part Number
82-3491
* Cornelius Part Number
All the dispensers have automatic agitation to keep the ice from clumping. If agitation is too frequent, the Pearl Ice will be damaged and will become
difficult to dispense. The Ice-O-Matic and Cornelius dispensers need to be set to 2 seconds on every 3 hours and the Lancer needs to be set to 4
seconds on, 150 seconds off.
The Ice-O-Matic and most Cornelius dispensers also have a restrictor plate at the outlet of the hopper. When used, that plate should be adjusted to be 1.5
inch open to limit the speed of the Pearl Ice flows out during dispensing.
Ice Machine Specifications
GEM0450A 2 21x24x27 115/60/1 Air 16.00 20 22
GEM0450W2 21x24x27 115/60/1 Water 14.35 20 18
GEM0650A2 21x24x27 115/60/1 Air 21.00 30 24
GEM0650W2 21x24x27 115/60/1 Water 19.50 30 19
GEM0650R2 21x24x27 115/60/1 Remote 23.50 30 208
GEM0655A2 21x24x27 230/50/1 Air 10.10 15 24
GEM0655W2 21x24x27 230/50/1 Water 9.50 15 19
GEM0956A 2 21x24x27 208-230/60/1 Air 11.80 15 30
GEM0956W2 21x24x27 208-230/60/1 Water 11.20 15 22
GEM0956R2 21x24x27 208-230/60/1 Remote 15.30 20 208
GEM0955A 2 21x24x27 230/50/1 Air 13.40 20 30
GEM0955W2 21x24x27 230/50/1 Water 13.10 15 22
MFI0500A2 21x24x27 115/60/1 Air 16.00 20 22
MFI0500W2 21x24x27 115/60/1 Water 14.35 20 18
MFI0800A2 21x24x27 115/60/1 Air 21.00 30 24
MFI0800W2 21x24x27 115/60/1 Water 19.50 30 19
MFI0800R2 21x24x27 115/60/1 Remote 23.50 30 208
MFI0805A2 21x24x27 230/50/1 Air 10.10 15 24
MFI0805W2 21x24x27 230/50/1 Water 9.50 15 19
MFI1256A2 21x24x27 208-230/60/1 Air 11.80 15 30
MFI1256W2 21x24x27 208-230/60/1 Water 11.20 15 22
MFI1256R2 21x24x27 208-230/60/1 Remote 15.30 20 208
MFI1255A2 21x24x27 230/50/1 Air 13.40 20 30
MFI1255W2 21x24x27 230/50/1 Water 13.10 15 22
Model
Number
WxDxH
(
Inches
)
Basic Electrical
Condenser
Minimum Circuit
Ampacity
Maximum Fuse
Size
Refrigerant Charge
oz. R404