Specification Sheet
Model Number
Description
Service Flow Rate
Max. gpm (lpm)
Pressure
Max. Psi (bar)
Inlet Water
Temp Range
F (C)
Micron
Rating
Approx.
Shipping Weight
lbs (kg)
IFQ Single Filter 1.5 (5.7)
10 - 125 (0.7 - 8.6)
100 (38)
.5
3 (1.3)
IFQXL Single Filter 2.25 (8.5) 100 (38) 5 (2.3)
IFQ Dual Filter 3.0 (11.4) 100 (38) 7 (3.2)
IFQSERIESFILTERSYSTEM
Snapshot
IFQ Series water treatment systems reduce sediment
down to 1/2 micron and reduce chlorine, taste and odor at a
flow rate of up to 3.0. The systems include IsoNet®, which
delivers consistent protection against the precipitation and
accumulation of scale and provides a protective barrier to
help guard against corrosion.
Features and Benefits
• Reduces maintenance frequency and cost, and extends
equipment life.
• Improves equipment operating efficiency
• Incorporates IsoNet – patented scale-inhibiting
technology.
• Gradient-density depth filtration reduces dirt, rust and
other debris as small as 1/2 micron to ensure clean,
clear ice and protect solenoids, valves and other fittings
against wear and plugging.
• High-capacity activated carbon filtration reduces taste
and odor and protects equipment against corrosive
chlorine.
• 1/4 turn QT "Quick-Twist" cartridge makes changing the
filter quick, easy and sanitary.
• Wall-mount bracket and full-flow inlet shut-off valve
make installation simple.
• NSF certified under Standard 42
WATERFILTERS
WATERFILTERS
Ice. Pure and Simple
Model Number Description
Service Flow Rate
Max. gpm (lpm)
Pressure
Max. Psi (bar)
Inlet Water
Temp Range
F (C)
Micron
Rating
Approx.
Shipping Weight
lbs (kg)
IFIC
Single Inline Cartridge 1/4”
compression
0.5 (1.9) 10 - 100 (.07 - 6.9) 35 - 100 (2 - 38) 10 2 (.9)
IFIC
Single Inline Cartridge 3/8”
compression
SINGLEINLINEFILTERCARTRIDGES
Installation Tips
• Feed-water connection to system should be COLD only.
• Do not exceed system specifications for temperature
and pressure.
• Allow 3" clearance below system for cartridge removal
and replacement.
• Connect filtered water line to ice connections only. Do
not use for condenser water.
• No activation procedure or flushing is required for
system to perform as specified.