Product Overview
Application Assistance
800.365.5525
visit us at: www.icmcontrols.com
Phone
315.233.5266
Fax
315.233.5276
LIS156
ICM1500 SERIES
OIL PRIMARY CONTROL
All features and specifications subject to change without notice.
with 15, 30 or 45 second lockout times
Features
• Controls oil burner, oil valve (if desired) and
the ignition transformer in response to a
call for heat
• Solid state flame sensing circuit
• LED on terminal strip indicates system
lockout
• Enclosed safety switch with external reset
button
• Mounts on standard 4 x 4 in. junction box;
select models may be mounted directly on
burner housing
• C554A Cadmium Sulfide Flame Detector
and 24 VAC thermostat required
• Direct replacement for popular competitive
models
Specifications
Ignition Type
• Intermittent
Timing, Safety Switch
• 15, 30 or 45 seconds
Mounting Bracket
• For mounting on a standard 4” X 4” junction box or
direct mounting on burner housing
Electrical Rating; Contacts (full load)
• 7.4 A @ 120 VAC; 3.7 A @ 240 VAC
Electrical Rating; Contacts (locked rotor)
• 44.4 A @ 120 VAC; 22.2 A @ 240 VAC
Dimensions
• 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
• 111 mm high x 104 mm wide x 64 mm deep
Temperature Range
• -30°F to +130°F
Approvals
• Underwriters Laboratories Inc
Dimensions
4.08”
3.38”
2.35”
2.03”
3.38”
4.41”
ø .18”
ICM1500 Series Cross Reference
Part Number Safety Timing Replaces
ICM1501 15 seconds Honeywell: R8184G4066, R8184G1161, R8184G1294
ICM1502 30 seconds Honeywell: R8184G4074, R8184G1179, R8184G1302, R8184G4033
ICM1503 45 seconds Carlin: 48245
Honeywell: R8184G4009, R8184G1138, R8184G1427, R8184G4025
Tempstar/Heil: 1147017
White Rodgers: 668-401