Brochure
LIS244
ICM866U
UNIVERSAL START ASSIST
Combines award-winning, high-powered relay output design with
advanced patented circuitry for greater precision and reliability!
Connection DiagramWiring Diagram Dimensions
7.86”
3.00”
1.52”
2.27”
2.50”
Line
Run
Winding
Start
Winding
R
Run Cap
Start Cap
N.C. Relay
S
C
Trigger
Specifications
• Voltage: 90-240 VAC
• Recommended range: 1/12 to 5 HP
• 145-175 Mfd 330V capacitor
Features
• Patented circuitry with differential voltage sensing
technology
– Monitors differential compressor auxiliary voltage
– Precisely engages/disengages the start capacitor
– Not affected by ambient temperatures
– Recycles instantly
• Self-adjusting to changes in voltages
– Does not rely on relay with pre-set, factory default ranges
– Eliminates guesswork in “tweener” applications
– Extends motor life
• Rated for 1/12 to 5HP applications
– Reduces inventory, saves money
– One model is all you need
• Simple, two-wire installation
– Faster install time
– Minimizes risk of accidental miswires
• Multi-voltage operation – 115 or 230 VAC motors
• 145-175 µF @ 330V
• UL Recognized
ICM866U Replaces
Supco: SPP5, SPP6, SPP5E, SPP6E, SPP7E, SPP8E, SPP9E, SPP10E
Kickstart: KS1, TO-5, KS8
5-2-1: CSR-U1, CSR-U2, CSR-U3
Watsco: WSX1
Mars: 32708, SS1, SS5, 32703, 32704, 32701, 32702
Diversitech: DST-5, DST-6