User's Manual

46
6
REMOTE JACK (CI-V) INFORMATION
*
1
When wide or normal operation is available, add 00 for wide operation
or 01 for normal operation; when normal or narrow operation is avail-
able, add 00 for normal operation or 01 for narrow operation; when
wide, normal and narrow operation is available, add 00 for wide oper-
ation, 01 for normal operation and 02 for narrow operation.
*
2
Memory channel number 1A=0100/1b=0101, 2A=0102/2b=0103,
3A=0104/3b=0105, C1=0106, C2=0107.
CCOOMMMMAANNDD TTAABBLLEE
CCnn SScc DDeessccrriippttiioonn
00 Send frequency data
01 x x Send mode data
02 Read band edge frequencies
03 Read display frequency
04 Read display mode
05 Set frequency data
00*
1
Set LSB
01*
1
Set USB
02*
1
Set AM
06 03*
1
Set CW
04*
1
Set RTTY
05*
1
Set FM
06*
1
Set WFM
Set to VFO
00 Set to VFO A
07 01 Set to VFO B
A0 VFO A=B
B0 Switch VFO A and B
08
Set to memory mode
mc*
2
Mch
09 Memory write
0A Memory to VFO
0B Memory clear
0C Read duplex offset frequency
0D Set duplex offset frequency
CCnn SScc DDeessccrriippttiioonn
0E
00 Scan stop
01 Scan start
00 Split OFF
01 Split ON
0F 10 Simplex mode
11 Duplex mode
12 Duplex + mode
00 10 Hz TS
01 100 Hz TS
02 1 kHz TS
03 5 kHz TS
04 9 kHz TS
10 05 10 kHz TS
06 12.5 kHz TS
07 20 kHz TS
08 25 kHz TS
09 100 kHz TS
11 x x ATT ON/OFF; 00=OFF; 20=ON
15
01 Read squelch condition
02 Read S-meter level
02 Preamp setting
12 AGC setting
16 22 NB setting
42 TONE setting
43 TSQL setting
44 COMP setting
46 VOX setting
47 BK-IN setting
19 00 Read transceiver ID code