User's Manual
110
16
CONTROL COMMAND
• Command table (continued)
0E A1–A7 Set ∂F scan span (A1=±5 kHz,
A2=±10 kHz, A3=±20 kHz,
A4=±50 kHz, A5=±100 kHz,
A6=±500 kHz, A7=±1 MHz)
B0 Set as non-select channel
B1 Set as select channel
D0 Set scan resume OFF
D3 Set scan resume ON
0F 00 Turn the split function OFF
01 Turn the split function ON
10 00 Select 10 Hz (1 Hz) tuning step
01 Select 100 Hz tuning step
02 Select 1 kHz tuning step
03 Select 5 kHz tuning step
04 Select 9 kHz tuning step
05 Select 10 kHz tuning step
06 Select 12.5 kHz tuning step
07 Select 20 kHz tuning step
08 Select 25 kHz tuning step
11 00 Attenuator OFF
06 Attenuator ON (6 dB)
12 Attenuator ON (12 dB)
18 Attenuator ON (18 dB)
12 00 Select/read antenna selection
01 (00=ANT1, 01=ANT2 : Add 0 or 1
to turn [RX ANT] OFF or ON, re-
spectively.)
13 00 Announce with voice synthesizer
01 (00=all data; 01=frequency and
02 S-meter level; 02=receive mode)
14 01 + Level data [AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data [RF] level setting (0=max. CCW to
255=11 o’clock)
03 + Level data [SQL] level setting (0=11 o’clock to
255=max. CW)
06 + Level data [NR] level setting (0=min. to
255=max.)
07 + Level data Inside [TWIN PBT] setting or IF
shift setting (0=max. CCW,
128=center, 255=max. CW)
08 + Level data Outside [TWIN PBT] setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data [CW PITCH] setting (0=low pitch to
255=high pitch)
0A + Level data [RF POWER] setting (0=mini. to
255=max.)
0B + Level data [MIC GAIN] setting (0=mini. to
255=max.)
0C + Level data [KEY SPEED] setting (0=slow to
255=fast)
0D + Level data [NOTCH] setting (0=low freq. to
255=high freq.)
0E + Level data [COMP] setting (0=mini. to
255=max.)
0F + Level data [BK-IN DELAY] setting (0=short
delay to 255=long delay)
10 + Level data [BAL] level setting (0=max. CCW,
128=center, 255=max. CW)
12 + Level data [NB] level setting (0=mini. to
255=max.)
15 + Level data Monitor gain setting (
0=0% to
255=100%)
14 16 + Level data VOX gain setting (0=0% to
255=100%)
17 + Level data Anti-VOX gain setting (0=0% to
255=100%)
18 + Level data LCD contrast setting (0=0% to
255=100%)
19 + Level data LCD bright setting (0=0% to
255=100%)
15 01 Read squelch condition
02 Read S-meter level
11 Read Po meter level
12 Read SWR meter level
13 Read ALC meter level
14 Read COMP meter level
16 02 Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
12 AGC selection (1=Fast; 2=Mid;
3=Slow)
22 Noise blanker (0=OFF; 1=ON)
40 Noise reduction (0=OFF; 1=ON)
41 Auto notch (0=OFF; 1=ON)
42 Repeater tone (0=OFF; 1=ON)
43 Tone squelch (0=OFF; 1=ON)
44
Speech compressor (0=OFF; 1=ON)
45 Monitor (0=OFF; 1=ON)
46 VOX function (0=OFF; 1=ON)
47 Break-in (0=OFF; 1=semi break-
in; 2=full break-in)
48 Manual notch (0=OFF; 1=ON)
49 RTTY filter (0=OFF; 1=ON)
4F Twin peak filter (0=OFF; 1=ON)
50 Dial lock (0=OFF; 1=ON)
19 00 Read the transceiver ID
1A 00 Send/read memory contents (see
p. 112 for details)
01 Send/read band stacking register
contents (see p. 112 for details)
02 Send/read memory keyer con-
tents (see p. 112 for details)
03 Send/read the selected filter width
(0=50 Hz to 40/31=3600/2700 Hz)
04 Send/read the selected AGC time
constant (0=OFF, 1=0.1/0.3 sec. to
13=6.0/8.0 sec.)
0501 Send/read SSB TX Tone (Bass)
level (0 =min. to 10=max.)
0502 Send/read SSB TX Tone (Treble)
level (0=min. to 10=max.)
0503 Send/read MONITOR gain (0=min.
to 255=max.)
0504 Send/read CW side tone gain
(0=min. to 255=max.)
0505 Send/read CW side tone gain limit
(0=OFF, 1=ON)
0506 Send/read beep gain (0=min. to
255=max.)
0507 Send/read beep gain limit (0=OFF,
1=ON)
0508 Send/read LCD contrast (0=0% to
255=100%)
0509 Send/read LCD backlight (0=0% to
255=100%)
Command Sub command Description Command Sub command Description