User's Manual

60
5
FUNCTION FOR RECEIVE
5
Twin PBT operation
General PBT (Passband Tuning) function electronically
narrows the IF passband width by shifting the IF fre-
quency to slightly outside of the IF lter passband to
reject interference. This transceiver uses the DSP cir-
cuit for the PBT function. Moving both [TWIN PBT]
controls to the same position shifts the IF.
The LCD shows the passband width and shift fre-
quency graphically.
Push [FILTER] for 1 sec. to enter the lter set mode.
Current passband width and shift frequency is dis-
played in the lter set mode screen.
To set the [TWIN PBT] controls to the center posi-
tions, push [PBT CLR] for 1 sec.
The variable range depends on the passband width
and mode. The edge of the variable range is half of the
passband width, and PBT is adjustable in 25 or 50 Hz
steps. These controls function as an IF shift control
while in AM mode and when the RTTY lter is turned
ON. Only the inner control may function in this case.
IF shift is adjustable in 20/40 Hz steps in RTTY (RTTY
lter is turned ON) or 150/300/500 Hz steps in AM.
[TWIN PBT] should normally be set to the center posi-
tions (PBT setting is cleared) when there is no interfer-
ence.
When PBT is used, the audio tone may be changed.
Not available for FM mode.
While rotating [TWIN PBT], noise may occur. This comes
from the DSP unit and does not indicate an equipment
malfunction.
PBT OPERATION EXAMPLE