Instruction Manual

12
52
SPECIFICATIONS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
General
Minimum range:
Maximum range:
Measurement range:
Preheat time:
Connection length
between display and scanner units:
25 m, 82 ft (when measurement range is
1
8 NM)
36 NM
1
8,
1
4,
1
2,
3
4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36 (NM)
90 seconds
15 m, 49.2 ft
Display unit
LCD display:
Resolution:
LCD mounting:
Input:
Output:
Power supply requirement:
Power consumption (at zero wind velocity):
Usable temperature range:
Dimensions (Including the mounting bracket):
(Projections not included)
Weight (Mounting bracket is included):
10.4-inch TFT Color LCD
480 × 640
Vertical
NMEA 0183 format (for navigation receiver),
N+1 format (uxgate compass sensor),
AUX,
IEC61162-2 format (for AIS unit)
NMEA 0183 format
12 V or 24 V DC (Power requirement: 10.2 ~ 42 V DC)
Approximately 55 W
–15˚C ~ +55˚C, +5˚F ~ 131˚F
301 (W) × 323.5 (H) × 119.2 (D) mm,
11.8 (W) × 12.7 (H) × 4.7 (D) inch
Approximately 4.3 kg, 9.5 lb
Scanner unit (EX-2714)
Type:
Rotation speed (typical):
Beam width (typical):
Side lobe (typical):
Polarization:
Transmission frequency:
Peak output power:
Pulse width:
Mixer and Local Oscillator:
Transmitting Tube:
Modulator:
Duplexer:
Tuning system:
Intermediate frequency:
IF Band width:
Dimensions:
Usable temperature range:
Relative Humidity:
Weight:
60 cm (2 ft.) Slotted Waveguide Array, enclosed in a radome.
24 rpm, 36 rpm
Horizontal beam
Vertical beam 22˚
–22 dB
Horizontal
9410 MHz ±30 MHz P0N
4 kW
80 ns / 2160 Hz, 80 ns / 1440 Hz, 250 ns / 1440 Hz, 350 ns /
1440 Hz, 900 ns / 720 Hz
Microwave Integrated Circuit
Magnetron (CHN and EXP versions) MAF1421B, (EUR version) MAF1611B
FET switching
Circulator
Automatic / manual selectable
(CHN and EXP versions) 250 MHz, (EUR version) 60 MHz
(CHN and EXP versions) 15 MHz / 3 MHz, (EUR version) 10 MHz / 3MHz
640 (W) × 256 (H) × 640 (D) mm,
25.2 (W) × 10.1 (H) × 25.2 (D) inch
–25˚C to +70˚C, –13˚F to 158˚F
Less than 95% at 40˚C (+104˚F)
Approximately 8 kg, 17.5 lb (without cable)
Options
L Some options may not be available, depending on the radar version.
OPC-2339 system cable
To install the display unit and scanner up to 20 m (65.6 ft) apart.
OPC-2340 system cable
To install the display unit and scanner up to 30 m (98.4 ft) apart.
UX-252 video output unit
To connect an external display or a PC monitor with a VGA connector.
L All stated specications are subject to change without notice or obligation.
MR-1010RII / Page 13-57