REPEATER OPERATION
Auto repeater function
(USA version only)
The USA version automatically activates the repeater settings
(duplex, ON/OFF, duplex direction, tone encoder ON/OFF)
when the operating frequency falls within or outside of the
general repeater output frequency range. The offset and re-
peater tone frequencies are not changed by the auto repeater
function. Reset these frequencies, if necessary.
q While pushing [
Y
Y
] and [
ZZ
], turn the power ON to enter
INI
-
TIAL SET MODE
.
w Push [
Y
Y
] or [
ZZ
] several times until “RPt” appears.
e Rotate [VOL] to select the desired condition.
“OF”— the auto repeater function is turned OFF;
“R1”— the auto repeater function activates for duplex only;
“R2”— the auto repeater function activates for duplex and tone.
r Push [
ENT
] (or [D•
CLR
]) to exit
INITIAL SET MODE
.
• Frequency range and offset direction
Repeater lockout
This function helps prevent interference to other stations by
inhibiting your transmission when a signal is received. The
transceiver has two inhibiting conditions, repeater and busy.
q While pushing [
Y
Y
] and [
ZZ
], turn the power ON to enter
INI
-
TIAL SET MODE
.
w Push [
Y
Y
] or [
ZZ
] several times until “RLO” appears.
e Rotate [VOL] to turn the repeater lockout function to “RP,”
“bU” or OFF.
“RP”: Transmit is inhibited when a signal with un-matched sub-
audible tone is received.
“bU”: Transmit is inhibited when a signal is received.
r Push [
ENT
] (or [D•
CLR
]) to exit
INITIAL SET MODE
.
USING
INITIAL SET MODE
USING
INITIAL SET MODE
Frequency range Duplex direction
145.200–145.495 MHz
“–” appears
146.610–146.995 MHz
147.000–147.395 MHz “+” appears