User's Manual
195
18
CONTROL COMMAND
D Data content description (continued)
q Frequency band setting
00 : HF/50 MHz frequency band
01 : 144 MHz band frequency band
02 : 430 MHz band frequency band
03 : 1200 MHz band frequency band
w, e Memory channel number
0001–0099 : Memory channel 0 to 99
0100 : Programmed scan edge 1A
0101 : Programmed scan edge 1b
0102 : Programmed scan edge 2A
0103 : Programmed scan edge 2b
0104 : Programmed scan edge 3A
0105 : Programmed scan edge 3b
0106 : Call channel
r Split and Select memory settings
XX
r
0: Select memory OFF
1: Select memory ON
0: Split OFF
1: Split ON
When the program channel is selected, both settings
should be “0.”
When the Call channel is selected, the Select mem-
ory setting should be “0.”
t–o Operating frequency setting
3EE@s/PERATINGFREQUENCY
!0, !1 Operating mode setting
3EE@s/PERATINGMODE
!2 $ATAMODESETTING
1 byte data (XX)
00: Data mode OFF
01: Data mode ON
!3 Duplex and Tone settings
XX
!3
0: OFF, 1: Tone
2: TSQL, 3: DTCS
0: Duplex OFF
1: − Duplex, 2: + Duplex
!4 Digital squelch setting
X0
!4
0: Digital squelch function OFF
1: Digital call sign squelch function ON (DSQL)
2: Digital code squelch function ON (CSQL)
!5–!7 Repeater tone frequency setting
!8–@0 Tone squelch frequency setting
3EE@s2EPEATERTONETONESQUELCHSETTING
@1–@3 DTCS code setting
3EE@s$4#3CODEANDPOLARITYSETTING
@4 Digital code squelch setting
3EE@s$IGITALCODESQUELCHSETTING
@5–@7 Duplex offset frequency setting
3EE@s$UPLEX/FFSETFREQUENCYSETTING
@8–#5 Destination call sign setting
(up to 8 characters)
#6–$3 R1 (Access/Area repeater) call sign setting
(up to 8 characters)
$4–%1 R2 (Link/Gateway repeater) call sign setting
(up to 8 characters)
3EE@s$648CALLSIGNSSETTING
%2–^0 Memory name setting
Up to 9 characters.
3EE@s#HARACTERCODESETTING
!BOUTCLEARINGOPERATION
“1A 00” command with the format as below clears the
data of the selected memory channel.
w, e : Memory channel 0 to 99
r : FF
t or later : None
NOTE:
s4HESAMEDATAASt–%1 are stored in t–%1.
s7HENTHE3PLITFUNCTIONIS/.THEDATAOFt–%1
is used for transmit.
s%VENIFTHE3PLITFUNCTIONIS/&&ENTERTHEDATA
into t–%1 to match your transceiver. We recom-
mend that you set the same data as t–%1.
s-EMORYCONTENTSETTING
Command : 1A 00
X
rqt〜o!0、!1 !2 !4 @4!3 !5〜!7 @5〜@7@1〜@3!8〜@0
XXX……XXXXXXXXXXX0XXXXXXXX XXXX XX XXXXXXXX XXXXXX XXXX
w、e
$4〜%1
XX……XX ……………… ……XX XX
t〜%1 %2〜^0#6〜$3
XX……XX
@8〜#5
XX……XX