User's Manual

176
16
OPTION INSTALLATION
16
N UT-121 DIGITAL UNIT INSTALLATION
N FL-430/FL-431
1ST IF FILTER INSTALLATION
The optional Roofing Filters, FL-430 1ST IF FILTER
(6 kHz) or FL-431 1ST IF FILTER (3 kHz) provides 6 or 3
kHz filtering to reduce interference from strong nearby
signals.
q Remove the top and bottom covers as shown on
page 174.
w Install the FL-430 or FL-431 as shown to the right.
s4HECONNECTORSONTHE)#AREMARKEDFORTHEAP-
propriate filter.
s%NSURETHE&,OR&,ISINSTALLEDCORRECTLY
e Return the top and bottom covers to the original po-
sitions.
FL-431 (3 kHz) FL-430 (6 kHz)
The optional UT-121 DIGITAL UNIT is required for DV
mode operation, including the DR mode.
q Remove the top and bottom covers as shown on
page 174.
w Remove the upper two screws from the front panel
(q).
e Loosen the lower two screws on the front panel
(w), then slowly fold down the front panel in the
direction of the arrow (e).
r Remove the protective paper from one side of the
double sided adhesive sheet (r), then place the
sheet on the panel, as shown below. (t).
t Remove the other side of the protective paper, and
install the UT-121 as shown below (y).
y Return the front panel, top and bottom covers to
their original positions.
Top
Bottom
Rear
Front
Top
Bottom
Rear
Front
q Remove
UT-121
q Remove
w Loosen
r
w
Loosen
t
e
y