CONTROL COMMAND
s"ANDEDGEFREQUENCYSETTING
Command 02*, 1E 01, 1E 03
q
XXX
wertyuio!0 !1 !2
XXXXXXXXX2DXXXXXXXXXX
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–9
1000 MHz digit: 0–1
100 MHz digit: 0–9
10 Hz digit: 0–9
1 Hz digit: 0–9
1 kHz digit: 0–9
100 Hz digit: 0–9
100 kHz digit: 0–9
10 kHz digit: 0–9
10 MHz digit: 0–9
1 MHz digit: 0–9
1000 MHz digit: 0–1
100 MHz digit: 0–9
Separator (fixed)
Lower edge Higher edge
Edge number*: 01–30
* Edge number setting is not necessary with com-
mand 02.
s"ANDSTACKINGREGISTER
Command : 1A 01
q
XXXX
w
When sending the contents, the codes, such as op-
erating frequency and operating mode*, should be
added after the register code, as shown below.
* See t to %1 on ‘Memory content setting’ for details.
(p. 195)
q Frequency band code
Code &REQBAND &REQUENCYRANGEUNIT-(Z
01 1.8 1.800000– 1.999999
02 3.5 3.400000– 4.099999
03 7 6.900000– 7.499999
04 10 9.900000–10.499999
05 14 13.900000–14.499999
06 18 17.900000–18.499999
07 21 20.900000–21.499999
08 24 24.400000–25.099999
09 28 28.000000–29.999999
10 50 50.000000–54.000000
11 VHF 108.000000–174.000000
12 UHF 420.000000–480.000000
13 1.2G 1240.000000–1320.000000
14 GENE Other than above
w Register code
Code 2EGISTERED.O
01 1 (latest)
02 2
03 3 (oldest)
For example, when reading the oldest contents in the
21 MHz band, the code “0703” is used.
s-EMORYKEYERCONTENTS
Command : 1A 02
X
q: Channel data
w&1: Text data
XXX
……
XX
01M1
02M2
03M3
04M4
s#HARACTERSCODE
#HARACTER ASCII code $ESCRIPTION
0–9 30–39 Number
A–Z 41–5A Alphabetical characters
a–z 61–7A Alphabetical characters
space 20 Word space
/ 2F Symbol
? 3F Symbol
, 2C Symbol
. 2E Symbol
@ 40 Symbol
^5E
e.g., to send BT, enter ^BT
1
2A Inserts contest number (can be
used for 1 channel only)
s#7MESSAGECONTENTS
Command : 17
Set a CW message of up to 30 characters.
s#HARACTERSCODE
#HARACTER ASCII code $ESCRIPTION
0–9 30–39 Number
A–Z 41–5A Alphabetical characters
a–z 61–7A Alphabetical characters
space 20 Word space
/ 2F Symbol
? 3F Symbol
. 2E Symbol
2D Symbol
, 2C Symbol
: 3A Symbol
27 Symbol
( 28 Symbol
) 29 Symbol
3D Symbol
+ 2B Symbol
22 Symbol
@ 40 Symbol
s“FF” stops sending CW messages.
s“^” is used to transmit a string of characters with
no inter-character space.
D Data content description (continued)