OPERATING GUIDE VHF TRANSCEIVERS iF1000 Series UHF TRANSCEIVERS iF2000 Series The photo shows the UHF transceivers.
IMPORTANT i We appreciate you choosing Icom for your communication needs. READ ALL INSTRUCTIONS carefully and completely The MDC 1200 signaling system is built into your IC-F1000/ IC-F2000 series transceiver. SAVE THIS OPERATING GUIDE — This operating Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries.
TABLE OF CONTENTS IMPORTANT........................................................................... i TABLE OF CONTENTS......................................................... ii 1 PANEL DESCRIPTION.................................................1–9 ■ Front, top and side panels.............................................1 ■ Function display............................................................3 ■ LED indicator.................................................................
1 PANEL DESCRIPTION ■ Front, top and side panels q ROTARY SELECTOR !0 ANTENNA CONNECTOR o LED INDICATOR w VOLUME CONTROL [VOL] e [Emer] Speaker i PTT SWITCH [PTT] r SPEAKERMICROPHONE JACK Microphone u [UP]/ [Upper]* u [DOWN]/ [Lower]* t FUNCTION DISPLAY y [P0], [P1], [P2], [P3] 10-KEY PAD * Names for the non-display type transceiver 1 There are three types of transceivers in the IC-F1000 and IC-F2000 series.
PANEL DESCRIPTION r SPEAKER-MICROPHONE JACK ➥➥ Connect optional equipment. NOTE: After turning OFF the transceiver, connect or disconnect the optional equipment. Jack cover NOTE: Attach the jack cover when optional equipment is not used. t FUNCTION DISPLAY ➥➥ Displays a variety of information such as the operating channel number, channel name, User Set mode contents, and so on. See page 3 for details. y DEALER-ASSIGNABLE KEYS [P0]–[P3] ➥➥ Desired functions can be independently programmed by your dealer.
1 PANEL DESCRIPTION ■ Function display r COMPANDER ICON ➥➥ Appears when the Compander function is ON. q w e r t y u i o !0 t SCRAMBLER ICON ➥➥ Appears when the Voice Scrambler function is ON. y BELL ICON ➥➥ Appears or blinks when a matched 2-Tone or 5-Tone is received, depending on the presetting. u SCAN ICON ➥➥ Appears or blinks while scanning. q SIGNAL STRENGTH INDICATOR ➥➥ Displays the relative receive signal strength level. w LOW POWER ICON ➥➥ Appears when low output power is selected.
R F /S Scan ■ LED indicator L ow BATT2 PANEL DESCRIPTION O L ow BATT1 O O G G The LED indicator indicates the status of various parameters of T X L ow BATT1 the transceiver as follows: (Reference: R=Red, G=Green, O=Orange) • Receiving • Cloning (reading or writing data) • Low Battery 2 (You must charge the battery.) G T X L ow BATT2 G G G G G G G G G G G • Low Battery 1 (You should charge the battery.
1 PANEL DESCRIPTION ■ Programmable function keys For the Non-display type transceivers, the following functions can be assigned to [Emer], [Upper], and [Lower]. For the Simple type transceivers and the 10-key type transceivers, the following functions can be assigned to [P0], [P1], [P2], [P3], [Emer], [Up], and [Down]. Consult your Icom dealer or system operator for details concerning your transceiver’s programming.
PANEL DESCRIPTION 1 MEMORY CHANNELS 1, 2, 3, 4 ➥➥ Push to directly select memory channel 1, 2, 3 or 4, if programmed. LOCK < for the Non-display type transceivers > ➥➥ Hold down this key to lock all programmable keys except the followings: [Moni], [Lock], [Emer], [Surveillance], [Siren], [Lone Worker], and [Shift].
1 PANEL DESCRIPTION C.Tone CH ENT // only for the Simple type and 10-key type transceivers // ➥➥ Push to enter the continuous tone selection mode. Select the tone frequency or DTCS code using [CH Up] or [CH Down]. TALK AROUND ➥➥ Push to turn the Talk Around function ON or OFF. • The Talk Around function equalizes the transmit frequency to the receive frequency for transceiver-to-transceiver communication. WIDE/NARROW ➥➥ Push to toggle the channel passband width between wide and narrow.
PANEL DESCRIPTION SURVEILLANCE < for the Non-display type transceivers > ➥➥ Hold down to turn ON the Surveillance function. ➥➥ Push to turn OFF the function. < for the Simple type and 10-key type transceivers > ➥➥ Push to turn the Surveillance function ON or OFF. • When this function is ON and a signal is received, a beep does not sound and the LED does not light, even if you push any key. SIREN ➥➥ Hold down to emit a siren sound.
1 PANEL DESCRIPTION TX CODE CH UP/DOWN // only for the PMR model (for the Simple type and 10-key type transceivers) // ➥➥ Push to select a preprogrammed TX code channel. ➥➥ Push to select a desired digit in the TX code edit mode. ID-MR SELECT // only for the PMR model (for the Simple type and 10-key type transceivers) // ➥➥ Push to recall the received ID code. • The transceiver can memorize up to 5 codes. ➥➥ Select a desired code by pushing [CH Up] or [CH Down].
BASIC OPERATION ■ Selecting a channel There are several types of channel selections. Methods may differ, depending on the presetting. Consult your dealer for details. NON-ZONE TYPE: To select the desired operating channel: ➥➥ Rotate [ROTARY SELECTOR]. ➥➥ Push [CH Up] or [CH Down]. ➥➥ Push one of [MR-CH 1] to [MR-CH 4]. ➥➥ Push [Prio A], [Prio B], [Prio A (Rewrite)] or [Prio B (Rewrite)]. ZONE TYPE: To select the desired operating channel: ➥➥ Push [Zone], then push [CH Up] or [CH Down].
2 BASIC OPERATION DDTransmitting notes • Transmit inhibit function The transceiver has several inhibit functions which restrict transmission under the following conditions: - The channel is busy. However, depending on the presettings, you can transmit when the call includes an unmatched (or matched) CTCSS (DTCS) tone. - The selected channel is a ‘receive only’ channel. • Time-out timer If continuous transmission exceeds the preprogrammed time-out timer limit, transmission is cut off.
BASIC OPERATION 2 ■ Emergency Call When pushing [Emergency] for the set time period*, the transceiver transmits an emergency signal once, or repeatedly, on the specified emergency channel. NOTE: Depending on the presetting, the following functions are automatically activated. Ask your dealer for details. The transceiver automatically transmits a repeat emergency signal until it receives an acknowledgement signal, or you turn OFF the transceiver power.
2 BASIC OPERATION ■ Lone Worker Emergency Call ■ Man Down Emergency Call When the Lone Worker function is ON, and if no operation occurs for a set time period*, the transceiver automatically enters the emergency mode. Then the countdown for the emergency call transmission starts. After a set time period* has passed, an emergency call is automatically transmitted once, or repeatedly*.
BASIC OPERATION ■ User set mode The User Set mode enables you to change various settings. You can “customize” the transceiver operation to suit your preferences and operating style. The display illustration is for the Simple type and 10-key type transceivers. < for the Non-display type transceivers > For settings of the microphone gain, the squelch level, the Beep level, the Beep function, and the Ringer level, see page 16 to 19.
2 BASIC OPERATION SQL (Squelch) Level Signal Moni • 0: SQL Open • 2: SQL Threshold • 9: SQL Tight • ON: Signaling beeps sound. • OFF: No signaling beeps sound. AF Min Level (Minimum audio output level) • 0 (minimum) – 255 (maximum) Mic Gain Higher values make the microphone more sensitive to the user's voice. • 1 (minimum) – 4 (maximum) 15 Lone Worker • ON: If no operation occurs for a set time period, the transceiver automatically enters the “Emergency” mode.
BASIC OPERATION ■ Setting the Beep function These instructions are for the non-display type transceivers. The Beep function can be turned ON or OFF. When it is OFF, the channel announcement is also turned OFF. [ROTARY SELECTOR] [VOL] NOTE: You should turn ON the Beep function when you set the Beep level, the Ringer level, the microphone gain, and the squelch level. qqRotate [VOL] to turn the transceiver power OFF. ww Set [ROTARY SELECTOR] to any channel other than Channel 16.
2 BASIC OPERATION ■ Setting the Beep level These instructions are for the non-display type transceivers. The Beep level is adjustable between 1 and 5, or 1 (linked) and 5 (linked). When a Linked option is selected, the beep audio level is adjustable by rotating [VOL]. qqRotate [VOL] to turn OFF the transceiver. ww Set [ROTARY SELECTOR] to any channel other than Channel 16. ee While holding down [Lower], rotate [VOL] to turn ON the power and enter the Beep level adjustment mode.
BASIC OPERATION 2 ■ Setting the Ringer level These instructions are for the non-display type transceivers. The Ringer level can be adjusted between 1 and 5, or 1 (Linked) and 5 (Linked). When a Linked option is selected, the ringer audio level is adjustable by rotating [VOL]. qqRotate [VOL] to turn OFF the transceiver power. wwSet [ROTARY SELECTOR] to Channel 16. ee While holding down [Lower], rotate [VOL] to turn ON the power and enter the Ringer level adjustment mode.
2 BASIC OPERATION ■ Setting the microphone gain ■ Setting the squelch level These instructions are for the non-display type transceivers. Adjust the microphone gain. These instructions are for the non-display type transceivers. The squelch circuit mutes the received audio signal, depending on the signal strength. qqRotate [VOL] to turn the transceiver power OFF. wwSet [ROTARY SELECTOR] to Channel 16.
MDC 1200 SYSTEM OPERATION ■ MDC 1200 system operation The MDC 1200 signaling system enhances your transceiver’s capabilities. You can receive or transmit PTT ID and Emergency calls. You can also receive Radio Check, Stun, and Revive calls. An additional feature of the MDC 1200 system included in Icom transceivers is called aliasing. Each transceiver on the system has a unique ID number. Aliasing is a substitute for this ID number and you can give an alphanumeric name for each station ID.
3 MDC 1200 SYSTEM OPERATION D Receiving an Emergency Call D Receiving a Stun or Revive Call q When an emergency call is received: • Beeps sound. • The calling station ID (or alias) and “ EMG EMG” are alternately displayed. • The operation of the backlight depends on the Backlight setting in the User set mode. When “LIGHT AUT” or “LIGHT AU2” is selected, the backlight turns ON for a set time period*.
MDC 1200 SYSTEM OPERATION 3 ■ Transmitting a call DDTransmitting a PTT ID You can notify another person of your station ID or alias. qqPush [PTT] to make a call. wwBeeps sound, depending on the presetting. ee Your alias or station ID will be transmitted when you push [PTT] (at the beginning of transmission) or release it (at the end of transmission), depending on the presetting.
A-7122-3EX-q © 2014 Icom Inc.