Command table (continued)
14
CONTROL COMMAND
1A 050023 Send/read CW side tone gain
(0=min. to 255=max.)
050024 Send/read CW side tone gain limit
(0=OFF, 1=ON)
050025 Send/read beep gain
(0=min. to 255=max.)
050026 Send/read beep gain limit
(0=OFF, 1=ON)
050027 Send/read headphones output
ratio (0=0.60 to 255=1.40)
050028 Send/read AF output level to ACC
(0=0% to 255=100%)
050029 Send/read S/P DIF output level
(0=0% to 255=100%)
050030 Send/read MOD output level to
ACC (0=0% to 255=100%)
050031 Send/read S/P DIF MOD output
level (0=0% to 255=100%)
050032 Send/read MOD input connector
during DATA OFF (0=MIC;
1=ACC; 2=MIC/ACC; 3=S/P DIF)
050033 Send/read MOD input connector
during DATA1
(0=MIC; 1=ACC; 2=MIC/ACC;
3=S/P DIF)
050034 Send/read MOD input connector
during DATA2
(0=MIC; 1=ACC; 2=MIC/ACC;
3=S/P DIF)
050035 Send/read MOD input connector
during DATA3
(0=MIC; 1=ACC; 2=MIC/ACC;
3=S/P DIF)
050036 Send/read relay type selection
(0=Lead, 1=MOS-FET)
050037 Send/read external meter output
selection
(0=Auto, 1=S, 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
D, 7=ID)
050038 Send/read external meter output
level (0=0% to 255=100%)
050039 Send/read reference signal in/out
setting (0=OFF, 1=IN, 2=OUT)
050040 Send/read reference signal fre-
quency setting
(0=0% to 255=100%)
050041 Send/read LCD unit backlight
brightness (0=0% to 255=100%)
050042 Send/read switch indicator bright-
ness (0=0% to 255=100%)
050043 Send/read screen image type
(0=A, 1=B)
050044 Send/read frequency readout font
(0=Basic (1), 1=Basic (2), 2=Italic,
3=Round, 4=Slim)
050045 Send/read meter response setting
(0=SLOW, 1=MID, 2=FAST)
050046 Send/read meter type
(0=Standard, 1=Edgewise, 2=Bar)
050047 Send/read meter type during wide
screen or mini scope indication
(0=Edgewise, 1=Bar)
050048 Send/read peak hold set for Bar
meter (0=OFF, 1=ON)
1A 050049 Send/read memory name indica-
tion setting (0=OFF, 1=ON)
050050 Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)
050051 Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)
050052 Send/read screen saver set
(0=OFF, 1=15 min., 2=30 min.,
3=60 min.)
050053 Set/read screen saver type
(0=Bound, 1=Rotation, 2=Twist)
050054 Send/read output signal setting for
external display (0=OFF, 1=ON)
050055 Send/read synchronous pulse
level setting (0=L, 1=H)
050056 Send/read opening message indi-
cation (0=OFF, 1=ON)
050057 Send/read opening message con-
tents (see p. 14-9 for details)
050058 Send/read date
(20000101=1st Jan. 2000 to
20991231=31st Dec. 2099)
050059 Send/read time
(0000=00:00 to 2359=23:59)
050060 Send/read CLOCK2 function
(0=OFF, 1=ON)
050061 Send/read offset time for CLOCK2
(240001=–24:00 to
240000=+24:00)
050062 Send/read CLOCK2 name
(up to 3-character; see p. 14-9)
050063 Send/read calibration marker
(0=OFF, 1=ON)
050064 Send/read confirmation beep
(0=OFF, 1=ON)
050065 Send/read band edge beep
(0=OFF, 1=ON)
050066 Send/read beep audio frequency
(50=500 Hz to 200=2000 Hz)
050067 Send/read quick split set
(0=OFF, 1=ON)
050068 Send/read FM split offset –9.999
to +9.999 MHz for HF
(see p. 14-10 for details)
050069 Send/read FM split offset –9.999
to +9.999 MHz for 50 MHz
(see p. 14-10 for details)
050070 Send/read split lock set
(0=OFF, 1=ON)
050071 Send/read tuner auto start set
(0=OFF, 1=ON)
050072 Send/read PTT tune set
(0=OFF, 1=ON)
050073 Send/read transverter set
(0=OFF, 1=ON)
050074 Send/read transverter offset
(see p. 14-10 for details)
050075 Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,
2=2125 Hz)
050076 Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)