Operation Manual

2
INSTALLATION AND CONNECTIONS
2-8
Linear Amplier Connections
EXCITER
1
1&2
Remote Control
cable
ACC cable
To an antenna
[ACC-1]
[REMOTE][ANT]
IC-PW1/EURO
Non-European versions: 100–120 / 200–240 V
European version: 230 V
[INPUT1]
7-pin side
[REMOTE]
Coaxial cable
[ANT1]
IC-7100
OPC-599
conversion
cable
[ACC]
GND
GND
GND
D
Connecting the IC-PW1/EURO
To connect the Icom IC-PW1/EURO, see the diagram below.
For IC-PW1/EURO operation, refer to the amplifier’s instruction manual.
AC outlet
D Connecting a non-Icom linear amplier
GND
HSEND
(Orange)
/VSEND
ALC (Blue)
13.8 V (Gray)
Relay
RF INRF OUT
ALC
SEND
Non-Icom Linear amplifier
To an antenna
[ANT1]*
2
13-pin plug with ACC cable
Switching diode
ACC
IC-7100
To connect a non-Icom HF, 50/70*
1
MHz bands linear amplifier, see the diagram below.
*
1
70 MHz band transmission is available, depending on the transceiver version.
*
2
When connecting a 144 MHz or 430 MHz band's liner am-
plifier, connect to [ANT2].