Operation Manual

10
SCANS
10-2
Scan types Scan Set mode
You can set the Scan speed and the Scan Resume
function in the Scan Set mode.
1. Open the SCAN screen.
MENU
» SCAN
2. Touch [SET].
• Opens the SCAN SET screen.
3. Select the desired item.
Rotate
Push
SCAN SET screen
4. Select the desired option.
L See below for details of the setting items and their
options.
5. To close the SCAN screen, push
EXIT
several
times.
The IC-7300 has several scan types as listed below.
Scan types Operation
Programmed
scan (p.10-3)
Repeatedly scans between 2 Scan
Edge frequencies (Scan Edge memory
channels P1 and P2).
The scan starts from the lower edge
frequency.
Memory
scan (p.10-4)
Repeatedly scans all entered Memory
channels.
Select
Memory
scan (p.10-4)
Repeatedly scans all or one of 3 select
Memory channels.
F scan
(p.10-6)
Repeatedly scans within the F span area.
The scan starts from the center frequency.
Preparation
D Squelch status
Scans work with the squelch status.
Be sure to adjust the squelch level according to your
operating conditions.
L When
AF RF/SQL
operates as only an RF gain
control, you cannot adjust the squelch level.
L Normally, set
AF RF/SQL
to the point where noise
disappears, and the TX/RX indicator goes off.
When the scan starts with the squelch open:
For a Programmed scan
When the tuning step is 1 kHz or less, the scan
continues until it is manually stopped— it does not
pause* even if signals are detected.
* The scan pauses when the squelch is closed and then
opened. The scan resumes after 10 seconds has passed
when the Scan Resume function is ON. It is cancelled
when the function is OFF.
When the tuning step is 5 kHz or more, the scan
pauses on each step when the Scan Resume function
is ON. It does not pause when the function is OFF.
For a memory scan
The scan pauses on each channel when the Scan
Resume function is ON. The scan does not pause
when the function is OFF.
When the scan starts with the squelch closed:
The scan stops when a signal is detected.
When the Scan Resume function is ON, the scan pauses
for 10 seconds after detecting a signal, then resumes 2
seconds after the signal disappears.
TIP: How to reset to the default setting
Touching the item or its option for 1 second displays
the Quick menu, and then touch “Default” to reset to
the default setting.
SCAN Speed (Default: Fast)
Set the desired scan speed to slow or fast.
• Slow: Scan speed is slow.
• Fast: Scan speed is fast.
SCAN Resume (Default: ON)
Set the scan resume function to ON or OFF.
• OFF: When a signal is detected, cancels the scan.
• ON: When a signal is detected, scan pauses for
10 seconds, then resumes. Two seconds after
the signal disappears, the scan resumes.