Operation Manual

10
SCANS
10-3
Programmed scan and Fine Programmed scan (VFO mode)
Programmed scan and Fine Programmed scan
Scan
Scan edge
P1 or P2
Scan edge
P2 or P1
Jump
Repeatedly scans between two Scan Edge frequencies.
The edge frequencies are preset in P1 and P2 as the
default.
P1: 0.500000 MHz P2: 29.999999 MHz
L To change the P1 and P2 Scan Edge Memory
channels, see “Entering memory channel contents”
(p. 9-3) for details.
L If the same frequencies are entered into P1 and
P2, the Programmed scan does not start.
L In the Fine Programmed scan, the scan speed
decreases when the squelch opens, but the
transceiver keeps scanning. The scan tuning step
changes to 10 Hz when the squelch opens.
D Programmed scan operation
1. Push
V/M
to select the VFO mode.
2. Select the operating mode in the MODE screen.
LYou can change the operating mode while scanning.
3. Select the desired tuning step in the TS screen.
LYou can change the tuning step while scanning.
4. Open the SCAN screen.
MENU
» SCAN
5. Touch [PROG] to start the Programmed scan.
Blinks
Blinks
While programmed scanning
L “PROGRAM SCAN” and the decimal points blink
while scanning.
6. Touch [PROG] to cancel the scan.
7. To close the SCAN screen, push
EXIT
.
D Fine Programmed scan operation
1. Start the Programmed scan.
L See steps 1 ~ 5 in “Programmed scan operation” to
the left for details.
2. While Programmed scanning, touch [FINE] to
switch to the File Programmed scan.
While Programmed scanning
While Fine Programmed scanning
Blinks
Blinks
L While Fine Programmed scanning, “FINE PROGRAM
SCAN” blinks instead of “PROGRAM SCAN.”
L Each time you touch [FINE], the Programmed scan
and the Fine Programmed scan are switched.
3. Touch [PROG] to cancel the scan.
4. To close the SCAN screen, push
EXIT
.