Operation Manual

19
CONTROL COMMAND
19-10
Remote control (CI-V) information (Continued)
Memory keyer character entries
Command: 1A 02
- Character codes
Character ASCII code Description
0–9 30–39 Numbers
A–Z 41–5A Letters
space 20 Word space
/ 2F Symbol
? 3F Symbol
, 2C Symbol
. 2E Symbol
@ 40 Symbol
^ 5E Example: to send
BT, enter ^4254
2A Inserts contest number
(can be used for 1 channel only)
X
q: Channel data
01M1 05
M5
02M2 06
M6
03: M3 07: M7
04: M4 08: M8
w&1: Text data
X X X
……
X X
Memory keyer content
Command: 1A 02
Memory content
Command : 1A 00
X
e ri o, !0 !1 !2!4 !5!7
X X X ... ...X X X X X X X X X X X X X X X X X XX XX X X X X X X X
q, w !8@7
q, w Memory channel numbers
0001–0099: Memory channel 01 to 99
0100: Programmed scan edge P1
0101: Programmed scan edge P2
e Select memory setting
LSet 0 for P1 and P2.
r~i Operating frequency setting
See “• Operating frequency.”
o, !0 Operating mode setting
See “• Operating mode.”
!1 Data mode and tone type settings
!2~!4 Repeater tone frequency setting
!5~!7 Tone squelch frequency setting
See “• Repeater tone/tone squelch settings.”
!8~@7 Memory name settings
Up to 10 characters.
See “• Codes for character entries”
To clear the memory channel contents on 1A 00:
q,w: Memory channel (0001~0099)
e: “FF”
r: None
0X
e
0=OFF
Fixed
1= 1
2= 2
3= 3
X X
!1
0: OFF, 1: TONE, 2: TSQL
0=Data mode OFF
1=Data mode ON