Operation Manual

About protection indications
The IC-7600 has a 2-step protection function to pro-
tect the final power amplifiers.
The protector monitors the power amplifier temper-
ature and activates when the temperature becomes
extremely high.
Power down transmission
Reduces the transmit output power to 50 W.
“LMT” appears beside the TX indicator (p. 14) dur-
ing transmit.
Transmission inhibit
Deactivates the transmitter.
The TX indicator (p. 14) is displayed in gray during
transmit.
When the protector is activated, wait until the
power amplifier cools down using the transceiver in
stand-by or receive condition.
NOTE: DO NOT turn the transceiver power OFF
when the protector is ON. If you do, the cooling fan
will not function and it will take longer to cool the
transceiver.
The power amplifier temperature can be monitored in
the multi-function meter, TEMP gauge.
Screen saver function
The IC-7600 has a screen saver function to protect
the LCD from the “burn-in” effect.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [SET] (F-6) to select set mode menu screen.
e Push [DISP] (F-3) to enter display set mode.
r Push [Y] (F-1) or [Z] (F-2) several times to select
the “Screen Saver Function” item.
t Rotate the main dial to select the desired time
period for the screen saver activation from 15, 30,
60 min. and OFF.
Deactivate the screen saver with “OFF” selection.
y Push [Z] (F-2) to select the “Screen Saver Type”
item.
u Rotate the main dial to select the screen saver type
from “Bound,” “Rotation” and “Twist.”
Push and hold [PREVIEW] (F-5) to display the indica-
tion for your reference.
i Push [EXIT/SET] twice to exit set mode.